CVE-2025-24008

Estado: AplazadaAlta (8.7)—

A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in transit. An attacker with network access could eavesdrop the connection and retrieve sensitive information, including obfuscated safety passwords.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

AV:N/PR:N sin UI indica red sin autenticación (T1190). Eavesdropping en conexión no cifrada expone datos sensibles (T1005) en red adyacente potencial (T1557: MITM).

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (2)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-24008",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-24008",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-05-13T19:01:56.717335Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.8
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 8.7,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SIRIUS 3RK3 Modular Safety System (MSS)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIRIUS Safety Relays 3SK2",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2025-05-13T10:15:22.943",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-222768.html",
      "source": "productcert@siemens.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-311"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in transit. An attacker with network access could eavesdrop the connection and retrieve sensitive information, including obfuscated safety passwords."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIRIUS 3RK3 Modular Safety System (MSS) (todas las versiones), SIRIUS Safety Relays 3SK2 (todas las versiones). Los dispositivos afectados no cifran los datos en tránsito. Un atacante con acceso a la red podría interceptar la conexión y obtener información confidencial, incluyendo contraseñas de seguridad ofuscadas."
    }
  ],
  "lastModified": "2026-06-17T08:57:52.797",
  "sourceIdentifier": "productcert@siemens.com"
}