CVE-2025-23400
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
CVSS
- Version: 4.0
- Vector: CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Base score: 7.3
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.16%
- Percentile among all scored CVEs: 4
- Score date: 10/1/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (2)
CWEs
- CWE-119
References
Raw JSON (NVD)
Show
{
"id": "CVE-2025-23400",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-23400",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-03-11T14:57:36.559116Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.3,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V14.3",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V14.3.0.13",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V2312",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2312.0009",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V2406",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2406.0007",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V2412",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2412.0002",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Tecnomatix Plant Simulation V2302",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2302.0021",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Tecnomatix Plant Simulation V2404",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2404.0010",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-03-11T10:15:17.340",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Teamcenter Visualization V14.3 (todas las versiones < V14.3.0.13), Teamcenter Visualization V2312 (todas las versiones < V2312.0009), Teamcenter Visualization V2406 (todas las versiones < V2406.0007), Teamcenter Visualization V2412 (todas las versiones < V2412.0002), Tecnomatix Plant Simulation V2302 (todas las versiones < V2302.0021), Tecnomatix Plant Simulation V2404 (todas las versiones < V2404.0010). La aplicación afectada es vulnerable a la corrupción de memoria mientras analiza archivos WRL especialmente manipulados. Esto podría permitir que un atacante ejecute código en el contexto del proceso actual."
}
],
"lastModified": "2026-06-17T08:54:04.023",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B4A3796F-02D6-4610-A8F7-2E454F3EAA96",
"versionEndExcluding": "14.3.0.13",
"versionStartIncluding": "14.0.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "45C7FFCF-D436-4512-8603-5126D574056F",
"versionEndExcluding": "2312.0009",
"versionStartIncluding": "2312.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0345247C-30A9-4891-A4A1-214171953B93",
"versionEndExcluding": "2406.0007",
"versionStartIncluding": "2406.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8B6ED5A4-84CE-4291-9C2B-C163612DEFB5",
"versionEndExcluding": "2412.0002",
"versionStartIncluding": "2412.0"
},
{
"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1931FE09-570E-4D37-B732-1BF2D8893FEE",
"versionEndExcluding": "2302.0021",
"versionStartIncluding": "2302.0"
},
{
"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8FCD6BE6-B2E7-4D13-8928-9F9B5A4DEDD4",
"versionEndExcluding": "2404.0010",
"versionStartIncluding": "2404.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}