« Volver al listado

CVE-2025-23398

Estado: AnalizadaAlta (7.3)—

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

AV:L + UI:P → explotación en cliente (abrir archivo WRL preparado). Corrupción de memoria permite ejecución de código arbitrario en el proceso.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-23398",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-23398",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-11T13:45:05.413293Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 7.3,
          "Automatable": "NOT_DEFINED",
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "PASSIVE",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V14.3",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V14.3.0.13",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V2312",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2312.0009",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V2406",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2406.0007",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V2412",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2412.0002",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Tecnomatix Plant Simulation V2302",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2302.0021",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Tecnomatix Plant Simulation V2404",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2404.0010",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2025-03-11T10:15:17.003",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Teamcenter Visualization V14.3 (todas las versiones &lt; V14.3.0.13), Teamcenter Visualization V2312 (todas las versiones &lt; V2312.0009), Teamcenter Visualization V2406 (todas las versiones &lt; V2406.0007), Teamcenter Visualization V2412 (todas las versiones &lt; V2412.0002), Tecnomatix Plant Simulation V2302 (todas las versiones &lt; V2302.0021), Tecnomatix Plant Simulation V2404 (todas las versiones &lt; V2404.0010). La aplicación afectada es vulnerable a la corrupción de memoria mientras analiza archivos WRL especialmente manipulados. Esto podría permitir que un atacante ejecute código en el contexto del proceso actual."
    }
  ],
  "lastModified": "2026-06-17T08:54:03.033",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B4A3796F-02D6-4610-A8F7-2E454F3EAA96",
              "versionEndExcluding": "14.3.0.13",
              "versionStartIncluding": "14.0.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "45C7FFCF-D436-4512-8603-5126D574056F",
              "versionEndExcluding": "2312.0009",
              "versionStartIncluding": "2312.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0345247C-30A9-4891-A4A1-214171953B93",
              "versionEndExcluding": "2406.0007",
              "versionStartIncluding": "2406.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8B6ED5A4-84CE-4291-9C2B-C163612DEFB5",
              "versionEndExcluding": "2412.0002",
              "versionStartIncluding": "2412.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1931FE09-570E-4D37-B732-1BF2D8893FEE",
              "versionEndExcluding": "2302.0021",
              "versionStartIncluding": "2302.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8FCD6BE6-B2E7-4D13-8928-9F9B5A4DEDD4",
              "versionEndExcluding": "2404.0010",
              "versionStartIncluding": "2404.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}