CVE-2025-23363
A vulnerability has been identified in Teamcenter V14.1 (All versions), Teamcenter V14.2 (All versions), Teamcenter V14.3 (All versions < V14.3.0.14), Teamcenter V2312 (All versions < V2312.0010), Teamcenter V2406 (All versions < V2406.0008), Teamcenter V2412 (All versions < V2412.0004). The SSO login service of affected applications accepts user-controlled input that could specify a link to an external site. This could allow an attacker to redirect the legitimate user to an attacker-chosen URL to steal valid session data. For a successful exploit, the legitimate user must actively click on an attacker-crafted link.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 6.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.56%
- Percentil entre todas las CVEs puntuadas: 45
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-601
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-23363",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-23363",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-02-11T16:25:01.651412Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 7.4,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 4,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 6.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "ACTIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Teamcenter V14.1",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter V14.2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter V14.3",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V14.3.0.14",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter V2312",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2312.0010",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter V2406",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2406.0008",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter V2412",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2412.0004",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-02-11T11:15:16.250",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-656895.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-601"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V14.1 (All versions), Teamcenter V14.2 (All versions), Teamcenter V14.3 (All versions < V14.3.0.14), Teamcenter V2312 (All versions < V2312.0010), Teamcenter V2406 (All versions < V2406.0008), Teamcenter V2412 (All versions < V2412.0004). The SSO login service of affected applications accepts user-controlled input that could specify a link to an external site. This could allow an attacker to redirect the legitimate user to an attacker-chosen URL to steal valid session data. For a successful exploit, the legitimate user must actively click on an attacker-crafted link."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Teamcenter (todas las versiones anteriores a V14.3.0.0). El servicio de inicio de sesión SSO de las aplicaciones afectadas acepta entradas controladas por el usuario que podrían especificar un enlace a un sitio externo. Esto podría permitir que un atacante redirija al usuario legítimo a una URL elegida por el atacante para robar datos válidos de la sesión. Para que la vulnerabilidad se aproveche con éxito, el usuario legítimo debe hacer clic activamente en un enlace creado por el atacante."
}
],
"lastModified": "2026-06-17T08:53:48.887",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1228F306-A2A2-4F0D-A008-B7FB72258710",
"versionEndExcluding": "14.3.0.14",
"versionStartIncluding": "14.3"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2BDF20D2-7A74-425A-8620-43DF9FF8D944",
"versionEndExcluding": "2312.0010",
"versionStartIncluding": "2312.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8EA12964-7485-4E67-ACB8-AB20F387DCA6",
"versionEndExcluding": "2406.0008",
"versionStartIncluding": "2406.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A3EC7C8A-965B-4F6F-B8D0-4E53EB7C04A1",
"versionEndExcluding": "2412.0004",
"versionStartIncluding": "2412.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:14.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D654DEC7-0D54-454B-88DC-6E1475C51E44"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:14.2:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7408DACC-970A-495E-87F4-B4A237FFE01C"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}