CVE-2025-23173
The Versa Director SD-WAN orchestration platform provides direct web-based access to uCPE virtual machines through the Director GUI. By default, the websockify service is exposed on port 6080 and accessible from the internet. This exposure introduces significant risk, as websockify has known weaknesses that can be exploited, potentially leading to remote code execution.
Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers.
Workarounds or Mitigation:
Restrict access to TCP port 6080 if uCPE console access is not necessary. Versa recommends that Director be upgraded to one of the remediated software versions.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.62%
- Percentil entre todas las CVEs puntuadas: 48
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access85 % - Impacto principal
T1059Command and Scripting Interpreterexecution80 %
Websockify expuesto en puerto 6080 accesible desde internet sin autenticación (PR:N, UI:N) permite RCE en uCPE. CWE-200 confirma exposición de información que facilita explotación remota.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-200
Referencias
- https://security-portal.versa-networks.com/emailbulletins/68526ee0dc94d6b9f2faf71c
- https://support.versa-networks.com/support/solutions/articles/23000024323-release-21-2-3
- https://support.versa-networks.com/support/solutions/articles/23000025680-release-22-1-2
- https://support.versa-networks.com/support/solutions/articles/23000026033-release-22-1-3
- https://support.versa-networks.com/support/solutions/articles/23000026708-release-22-1-4
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-23173",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-23173",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-06-23T15:49:07.215724Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "support@hackerone.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "support@hackerone.com",
"affectedData": [
{
"vendor": "Versa",
"product": "Director",
"versions": [
{
"status": "affected",
"version": "21.2.2",
"versionType": "semver",
"lessThanOrEqual": "21.2.2"
},
{
"status": "affected",
"version": "21.2.3",
"versionType": "semver",
"lessThanOrEqual": "21.2.3"
},
{
"status": "affected",
"version": "22.1.1",
"versionType": "semver",
"lessThanOrEqual": "22.1.1"
},
{
"status": "affected",
"version": "22.1.2",
"versionType": "semver",
"lessThanOrEqual": "22.1.2"
},
{
"status": "affected",
"version": "22.1.3",
"versionType": "semver",
"lessThanOrEqual": "22.1.3"
},
{
"status": "affected",
"version": "22.1.4",
"versionType": "semver",
"lessThanOrEqual": "22.1.4"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-06-19T00:15:21.977",
"references": [
{
"url": "https://security-portal.versa-networks.com/emailbulletins/68526ee0dc94d6b9f2faf71c",
"tags": [
"Vendor Advisory"
],
"source": "support@hackerone.com"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000024323-release-21-2-3",
"tags": [
"Product"
],
"source": "support@hackerone.com"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000025680-release-22-1-2",
"tags": [
"Product"
],
"source": "support@hackerone.com"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000026033-release-22-1-3",
"tags": [
"Product"
],
"source": "support@hackerone.com"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000026708-release-22-1-4",
"tags": [
"Product"
],
"source": "support@hackerone.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Versa Director SD-WAN orchestration platform provides direct web-based access to uCPE virtual machines through the Director GUI. By default, the websockify service is exposed on port 6080 and accessible from the internet. This exposure introduces significant risk, as websockify has known weaknesses that can be exploited, potentially leading to remote code execution. \r\n\r\nVersa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. \r\n\r\nWorkarounds or Mitigation: \r\n\r\nRestrict access to TCP port 6080 if uCPE console access is not necessary. Versa recommends that Director be upgraded to one of the remediated software versions."
},
{
"lang": "es",
"value": "La plataforma de orquestación Versa Director SD-WAN proporciona acceso web directo a las máquinas virtuales uCPE a través de la interfaz gráfica de Director. De forma predeterminada, el servicio websockify está expuesto en el puerto 6080 y es accesible desde internet. Esta exposición supone un riesgo significativo, ya que websockify presenta vulnerabilidades conocidas que pueden explotarse, lo que podría provocar la ejecución remota de código. Versa Networks no tiene constancia de ningún caso reportado de explotación de esta vulnerabilidad. Investigadores de seguridad externos han publicado una prueba de concepto de esta vulnerabilidad. Soluciones alternativas o mitigación: Restrinja el acceso al puerto TCP 6080 si no necesita acceder a la consola uCPE. Versa recomienda actualizar Director a una de las versiones de software corregidas."
}
],
"lastModified": "2026-09-08T19:29:38.863",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:21.2.2:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "59E2F7B6-200B-4008-A5C6-FD33B05DFF8F"
},
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:21.2.3:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BB85151A-2B0A-4C44-A63A-B521A1578A4B"
},
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:22.1.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BE334340-8D19-4A10-AB58-B9028D96851C"
},
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:22.1.2:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2EB7153D-77F2-47E1-BEE0-F2071DF8C21A"
},
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:22.1.3:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C0CB9A88-8347-45E9-8E80-F46FE1391B8C"
},
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:22.1.4:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "272A25D5-8B29-4919-9C8A-D36DE8B592BF"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "support@hackerone.com"
}