Estado: AnalizadaAlta (7.8)—

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to execution of commands with elevated privileges.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

AV:L sin UI:R indica acceso local sin interacción. CWE-77 (command injection) con ejecución de comandos con privilegios elevados = T1068 con impacto T1059.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-22472",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-22472",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-18T03:55:30.367969Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "security_alert@emc.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "security_alert@emc.com",
      "affectedData": [
        {
          "vendor": "Dell",
          "product": "SmartFabric OS10 Software",
          "versions": [
            {
              "status": "affected",
              "version": "10.5.4.x"
            },
            {
              "status": "affected",
              "version": "10.5.5.x"
            },
            {
              "status": "affected",
              "version": "10.5.6.x"
            },
            {
              "status": "affected",
              "version": "10.6.0.x"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-03-17T18:15:20.930",
  "references": [
    {
      "url": "https://www.dell.com/support/kbdoc/en-us/000289970/dsa-2025-070-security-update-for-dell-networking-os10-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security_alert@emc.com"
    },
    {
      "url": "https://www.dell.com/support/kbdoc/en-us/000293638/dsa-2025-069-security-update-for-dell-networking-os10-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security_alert@emc.com"
    },
    {
      "url": "https://www.dell.com/support/kbdoc/en-us/000294091/dsa-2025-079-security-update-for-dell-networking-os10-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security_alert@emc.com"
    },
    {
      "url": "https://www.dell.com/support/kbdoc/en-us/000295014/dsa-2025-068-security-update-for-dell-networking-os10-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security_alert@emc.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "security_alert@emc.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to execution of commands with elevated privileges."
    },
    {
      "lang": "es",
      "value": "Dell SmartFabric OS10 Software, versiones 10.5.4.x, 10.5.5.x, 10.5.6.x y 10.6.0.x, contiene una vulnerabilidad de neutralización incorrecta de elementos especiales utilizados en un comando (inyección de comandos). Un atacante con privilegios bajos y acceso local podría explotar esta vulnerabilidad, lo que provocaría la ejecución de comandos con privilegios elevados."
    }
  ],
  "lastModified": "2026-06-17T08:47:36.590",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "14A2BCBC-C50A-4B11-9871-B84254872EEA",
              "versionEndExcluding": "10.5.4.14",
              "versionStartIncluding": "10.5.4.0"
            },
            {
              "criteria": "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A05AAE8C-8DCD-44E9-AC99-0C32F9BD80E4",
              "versionEndExcluding": "10.5.5.13",
              "versionStartIncluding": "10.5.5.0"
            },
            {
              "criteria": "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "430E412C-6FB3-437C-90D7-C73CBF498801",
              "versionEndExcluding": "10.5.6.8",
              "versionStartIncluding": "10.5.6.0"
            },
            {
              "criteria": "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E8DC8731-306C-4D6B-84FA-3F13B9E677B1",
              "versionEndExcluding": "10.6.0.2",
              "versionStartIncluding": "10.6.0.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security_alert@emc.com"
}