CVE-2025-1960
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.51%
- Percentil entre todas las CVEs puntuadas: 42
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access85 % - Impacto principal
T1078.001Default Accountsstealth · persistence · privilege escalation · initial access80 % - Impacto secundario
T1059Command and Scripting Interpreterexecution75 %
Vector CVSS N/N/N indica red sin autenticación (T1190). CWE-1188 sobre credenciales por defecto sin cambiar permite obtener acceso con T1078.001 (credenciales válidas). La ejecución de comandos no autorizados mencionada es impacto secundario.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
CWE
- CWE-1188
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-1960",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-1960",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-03-12T15:56:56.322926Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "WebHMI – Deployed with EcoStruxure Power Automation System",
"versions": [
{
"status": "affected",
"version": "WebHMI v4.1.0.0 and prior when deployed with EPAS User Interface 2.6.30.19 and prior"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-03-12T16:15:20.797",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-070-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-070-03.pdf",
"source": "cybersecurity@se.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-1188"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an\nattacker to execute unauthorized commands when a system’s default password credentials have not been\nchanged on first use. The default username is not displayed correctly in the WebHMI interface."
},
{
"lang": "es",
"value": "CWE-1188: Existe una vulnerabilidad de inicialización de un recurso con un valor predeterminado inseguro que podría provocar que un atacante ejecute comandos no autorizados cuando las credenciales de contraseña predeterminadas de un sistema no se hayan cambiado en el primer uso. El nombre de usuario predeterminado no se muestra correctamente en la interfaz WebHMI."
}
],
"lastModified": "2026-06-17T08:40:26.117",
"sourceIdentifier": "cybersecurity@se.com"
}