CVE-2025-1868
Vulnerability of unauthorized exposure of confidential information affecting Advanced IP Scanner and Advanced Port Scanner. It occurs when these applications initiate a network scan, inadvertently sending the NTLM hash of the user performing the scan. This vulnerability can be exploited by intercepting network traffic to a legitimate server or by setting up a fake server, in both local and remote scenarios. This exposure is relevant for both HTTP/HTTPS and SMB protocols.
CVSS
- Version: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Base score: 6.9
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.25%
- Percentile among all scored CVEs: 15
- Score date: 10/5/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (2)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
CWEs
- CWE-200
- CWE-200
References
Raw JSON (NVD)
Show
{
"id": "CVE-2025-1868",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-1868",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-03-03T12:05:32.379437Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.8,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 4.2,
"exploitabilityScore": 2.5
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 6.9,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cve-coordination@incibe.es",
"affectedData": [
{
"vendor": "Famatech Corp",
"product": "Advanced IP Scanner",
"versions": [
{
"status": "unaffected",
"version": "2.5.4594.1 and earlier"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Famatech Corp",
"product": "Advanced Port Scanner",
"versions": [
{
"status": "unaffected",
"version": "2.5.3869 and earlier"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-03-03T11:15:15.657",
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/information-display-multiple-products-famatech-corp",
"source": "cve-coordination@incibe.es"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Vulnerability of unauthorized exposure of confidential information affecting Advanced IP Scanner and Advanced Port Scanner. It occurs when these applications initiate a network scan, inadvertently sending the NTLM hash of the user performing the scan. This vulnerability can be exploited by intercepting network traffic to a legitimate server or by setting up a fake server, in both local and remote scenarios. This exposure is relevant for both HTTP/HTTPS and SMB protocols."
},
{
"lang": "es",
"value": "Vulnerabilidad de exposición no autorizada de información confidencial que afecta a Advanced IP Scanner y Advanced Port Scanner. Se produce cuando estas aplicaciones inician un escaneo de red, enviando inadvertidamente el hash NTLM del usuario que realiza el escaneo. Esta vulnerabilidad se puede explotar interceptando el tráfico de red hacia un servidor legítimo o configurando un servidor falso, tanto en escenarios locales como remotos. Esta exposición es relevante tanto para protocolos HTTP/HTTPS como SMB."
}
],
"lastModified": "2026-06-17T08:39:56.203",
"sourceIdentifier": "cve-coordination@incibe.es"
}