CVE-2025-1609
Estado: AnalizadaMedia (5.3)—
A vulnerability has been found in LB-LINK AC1900 Router 1.0.2 and classified as critical. Affected by this vulnerability is the function websGetVar of the file /goform/set_cmd. The manipulation of the argument cmd leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 10%
- Percentil entre todas las CVEs puntuadas: 96
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-77, CWE-78
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-1609",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-1609",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-02-24T11:50:01.097691Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 6.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.3,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "LOW",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "LB-LINK",
"product": "AC1900 Router",
"versions": [
{
"status": "affected",
"version": "1.0.2"
}
]
}
]
}
],
"published": "2025-02-24T02:15:32.097",
"references": [
{
"url": "https://noisy-caravel-a9a.notion.site/LBLINK_AC1900_V1-0-2_-set_cmd-_-bs_SetCmd-_CI-179898c94eac808e8875e0b8e1bee47e?pvs=74",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.296599",
"tags": [
"Permissions Required",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.296599",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.501023",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-77"
},
{
"lang": "en",
"value": "CWE-78"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in LB-LINK AC1900 Router 1.0.2 and classified as critical. Affected by this vulnerability is the function websGetVar of the file /goform/set_cmd. The manipulation of the argument cmd leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se ha encontrado una vulnerabilidad en el enrutador LB-LINK AC1900 1.0.2 y se ha clasificado como crítica. Esta vulnerabilidad afecta a la función websGetVar del archivo /goform/set_cmd. La manipulación del argumento cmd provoca la inyección de comandos del sistema operativo. El ataque se puede ejecutar de forma remota. El exploit se ha divulgado al público y puede utilizarse. Se contactó al proveedor con anticipación sobre esta divulgación, pero no respondió de ninguna manera."
}
],
"lastModified": "2026-06-17T08:39:27.350",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:lb-link:ac1900_firmware:1.0.2:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "88F9AE38-570C-4438-B271-BAF6B7D7807F"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:lb-link:ac1900:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4D158B70-2243-44AF-8AAF-DA319BC767BD"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}