« Volver al listado

CVE-2025-15113

Estado: ModificadaCrítica (9.8)—

Ksenia Security lares (legacy model) Home Automation version 1.6 contains an unprotected endpoint vulnerability that allows authenticated attackers to upload MPFS File System binary images. Attackers can exploit this vulnerability to overwrite flash program memory and potentially execute arbitrary code on the home automation system's web server.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Vector CVSS:3.1/AV:N/AC:L/PR:N indica acceso remoto sin privilegios previos. Upload de binarios MPFS permite sobrescribir memoria flash y ejecutar código arbitrario en el servidor web del sistema de automatización.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-15113",
  "cveTags": [
    {
      "tags": [
        "unsupported-when-assigned"
      ],
      "sourceIdentifier": "disclosure@vulncheck.com"
    }
  ],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-15113",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-01-02T14:23:42.640039Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "disclosure@vulncheck.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 9.3,
          "attackVector": "LOCAL",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 2.5
      },
      {
        "type": "Secondary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "disclosure@vulncheck.com",
      "affectedData": [
        {
          "vendor": "Ksenia Security S.p.A.",
          "product": "lares",
          "versions": [
            {
              "status": "affected",
              "version": "1.6"
            },
            {
              "status": "affected",
              "version": "1.0.0.15"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-12-30T23:15:49.913",
  "references": [
    {
      "url": "https://packetstorm.news/files/id/190178/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.kseniasecurity.com/",
      "tags": [
        "Product"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.vulncheck.com/advisories/ksenia-security-lares-home-automation-remote-code-execution-via-mpfs-upload",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5930.php",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5930.php",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "disclosure@vulncheck.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-256"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Ksenia Security lares (legacy model) Home Automation version 1.6 contains an unprotected endpoint vulnerability that allows authenticated attackers to upload MPFS File System binary images. Attackers can exploit this vulnerability to overwrite flash program memory and potentially execute arbitrary code on the home automation system's web server."
    },
    {
      "lang": "es",
      "value": "Ksenia Security Lares 4.0 Home Automation versión 1.6 contiene una vulnerabilidad de endpoint desprotegido que permite a atacantes autenticados cargar imágenes binarias del sistema de archivos MPFS. Los atacantes pueden explotar esta vulnerabilidad para sobrescribir la memoria de programa flash y potencialmente ejecutar código arbitrario en el servidor web del sistema de automatización del hogar."
    }
  ],
  "lastModified": "2026-06-17T08:37:09.730",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:kseniasecurity:lares_firmware:1.6:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "DF94F084-2F13-427A-9CB5-9E3E95621C8B"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:kseniasecurity:lares:4.0:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "DDE71F37-880F-4534-80FF-A2BE3D8E2AD4"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "disclosure@vulncheck.com"
}