CVE-2025-15023
Incorrect Authorization vulnerability in Yordam Information Technology Consulting, Training and Electronic Systems Industry and Trade Inc. Library Automation System allows Exploiting Incorrectly Configured Access Control Security Levels.
This issue affects Library Automation System: from v.19.5 before v.22.1.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.22%
- Percentil entre todas las CVEs puntuadas: 11
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution85 % - Impacto principal
T1078Valid Accountsstealth · persistence · privilege escalation · initial access80 %
UI:R + acceso remoto (AV:N) → ejecución en cliente. CWE-863 (autorización incorrecta) permite obtener acceso no autorizado (T1078) y potencialmente manipular datos en el sistema (T1565.001).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-863
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-15023",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-15023",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-05-14T18:36:08.369888Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "iletisim@usom.gov.tr",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "iletisim@usom.gov.tr",
"affectedData": [
{
"vendor": "Yordam Information Technology Consulting, Training and Electronic Systems Industry and Trade Inc.",
"product": "Library Automation System",
"versions": [
{
"status": "affected",
"version": "v.19.5",
"lessThan": "v.22.1",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-05-14T18:16:34.527",
"references": [
{
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-26-0240",
"source": "iletisim@usom.gov.tr"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "iletisim@usom.gov.tr",
"description": [
{
"lang": "en",
"value": "CWE-863"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect Authorization vulnerability in Yordam Information Technology Consulting, Training and Electronic Systems Industry and Trade Inc. Library Automation System allows Exploiting Incorrectly Configured Access Control Security Levels.\n\nThis issue affects Library Automation System: from v.19.5 before v.22.1."
},
{
"lang": "es",
"value": "Vulnerabilidad de autorización incorrecta en el Sistema de Automatización de Bibliotecas de Yordam Information Technology Consulting, Training and Electronic Systems Industry and Trade Inc. permite explotar niveles de seguridad de control de acceso configurados incorrectamente.\n\nEste problema afecta al Sistema de Automatización de Bibliotecas: desde la v.19.5 anterior a la v.22.1."
}
],
"lastModified": "2026-09-30T21:10:00.190",
"sourceIdentifier": "iletisim@usom.gov.tr"
}