CVE-2025-1449

Estado: AplazadaAlta (7.5)—

A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve's Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Acceso remoto con PR:H (requiere admin); variable sin sanitizar permite ejecución de comandos arbitrarios en contenedor; T1210 por red con privilegios elevados. Impactos: T1059 (ejecución de comandos), T1068 (escalada contextual dentro del contenedor).

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-1449",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-1449",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-31T17:53:19.410844Z"
        }
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "PSIRT@rockwellautomation.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 7.5,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "PRESENT",
          "privilegesRequired": "HIGH",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "PSIRT@rockwellautomation.com",
      "affectedData": [
        {
          "vendor": "Rockwell Automation",
          "product": "Verve Asset Manager",
          "versions": [
            {
              "status": "affected",
              "version": "<=1.39"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-03-31T16:15:22.770",
  "references": [
    {
      "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1723.html",
      "source": "PSIRT@rockwellautomation.com"
    }
  ],
  "vulnStatus": "Deferred",
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve's Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad en Rockwell Automation Verve Asset Manager debido a una depuración insuficiente de variables. Una parte de la interfaz web administrativa de la función Inventario de Dispositivos sin Agente (ADI) heredada de Verve (obsoleta desde la versión 1.36) permite a los usuarios modificar una variable con una depuración insuficiente. De ser explotada, podría permitir que un atacante con acceso administrativo ejecute comandos arbitrarios en el contexto del contenedor que ejecuta el servicio."
    }
  ],
  "lastModified": "2026-06-17T08:39:09.320",
  "sourceIdentifier": "PSIRT@rockwellautomation.com"
}