« Volver al listado

CVE-2025-14135

Estado: AnalizadaAlta (7.4)—

A vulnerability was identified in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function AP_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Desbordamiento de búfer en función remota (mod_form.so) accesible con PR:L (privilegios de usuario). Stack overflow típicamente permite ejecución de código (T1059) y escalada a root (T1068). Vector CVSS N/L sin UI determina T1210.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (6)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-14135",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-14135",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-12-08T17:06:40.827143Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "version": "2.0",
          "baseScore": 9,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "authentication": "SINGLE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 7.4,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "PROOF_OF_CONCEPT",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "cna@vuldb.com",
      "affectedData": [
        {
          "vendor": "Linksys",
          "product": "RE6500",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        },
        {
          "vendor": "Linksys",
          "product": "RE6250",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        },
        {
          "vendor": "Linksys",
          "product": "RE6300",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        },
        {
          "vendor": "Linksys",
          "product": "RE6350",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        },
        {
          "vendor": "Linksys",
          "product": "RE7000",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        },
        {
          "vendor": "Linksys",
          "product": "RE9000",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        }
      ]
    }
  ],
  "published": "2025-12-06T12:15:46.527",
  "references": [
    {
      "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md#poc",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?ctiid.334524",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?id.334524",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?submit.697982",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://www.linksys.com/",
      "tags": [
        "Product"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
    },
    {
      "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md#poc",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cna@vuldb.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        },
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was identified in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function AP_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Se identificó una vulnerabilidad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esto afecta a la función AP_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 conduce a un desbordamiento de búfer basado en pila. El ataque puede iniciarse remotamente. El exploit está disponible públicamente y podría ser utilizado. El proveedor fue contactado con antelación sobre esta divulgación, pero no respondió de ninguna manera."
    }
  ],
  "lastModified": "2026-09-25T23:10:00.463",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com"
}