CVE-2025-13902
Estado: AnalizadaMedia (5.1)—
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.22%
- Percentil entre todas las CVEs puntuadas: 12
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (4)
CWE
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-13902",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-13902",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-03-10T18:17:03.131045Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 5.4,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 2.3
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "Modicon Controllers M241/M251",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.4.13.12"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Modicon Controllers M258/LMC058",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-03-10T18:17:52.223",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf",
"tags": [
"Vendor Advisory",
"Mitigation",
"Patch"
],
"source": "cybersecurity@se.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad CWE-79 de Neutralización Incorrecta de la Entrada Durante la Generación de Páginas Web ('cross-site scripting') que podría causar una condición en la que atacantes autenticados pueden hacer que el navegador de una víctima ejecute JavaScript arbitrario cuando la víctima pasa el cursor sobre un elemento creado maliciosamente en un servidor web que contiene la carga útil inyectada."
}
],
"lastModified": "2026-06-23T14:41:40.273",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m258_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "72CC6066-2CD5-4516-8DE0-178301A1355C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m258:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FFBF6514-3E32-4C8E-81BA-D6464824351F"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_lmc058_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "47CDA6D7-419A-4517-B666-762B46D1DCA1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_lmc058:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0DFCD3D7-B85B-4C9E-B80C-B83B017183AA"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4D5BD37D-AD63-4A0B-B959-1F731D39E51C",
"versionEndExcluding": "5.4.13.12"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B8E03A25-B0B6-4BA2-80BC-52C16A6837E0"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "31DCF35D-C99C-4FB5-926C-09782051FC9A",
"versionEndExcluding": "5.4.13.12"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4D8FD9D9-F59F-470E-9F7F-CDDD80B0633C"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}