CVE-2025-13845
CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.35%
- Percentil entre todas las CVEs puntuadas: 27
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution85 % - Impacto principal
T1059Command and Scripting Interpreterexecution80 %
Vulnerabilidad Use After Free (CWE-416) que requiere importar un archivo malicioso (SSD) con interacción del usuario en aplicación local (AV:L, UI:A), permitiendo ejecución de código remoto.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-416
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-13845",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-13845",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-01-15T18:52:53.300481Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.4,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "ACTIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "EcoStruxure Power Build Rapsody",
"versions": [
{
"status": "affected",
"version": "FR v2.8.1.0300 and prior"
},
{
"status": "affected",
"version": "ESP v2.8.5.0200 and prior"
},
{
"status": "affected",
"version": "PT v2.8.7.0100 and prior"
},
{
"status": "affected",
"version": "BEL (FR) v2.8.8.0100 and prior"
},
{
"status": "affected",
"version": "BEL (EN) v2.8.3.0100 and prior"
},
{
"status": "affected",
"version": "INT (EN) v2.8.4.0300 and prior"
},
{
"status": "affected",
"version": "NL v2.8.2.0000 and prior"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-01-15T19:16:02.937",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-04.pdf",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-416"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody."
},
{
"lang": "es",
"value": "CWE-416: Vulnerabilidad Use After Free que podría causar ejecución remota de código cuando el usuario final importa el archivo de proyecto malicioso (archivo SSD) en Rapsody."
}
],
"lastModified": "2026-09-03T03:15:22.217",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:fr:*:*:*",
"vulnerable": true,
"matchCriteriaId": "139FB737-5979-4991-B8D1-0289CE7BFC26",
"versionEndIncluding": "2.8.1.0300"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:nl:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3112F8F2-CA70-42A5-B9CC-B45D4505713C",
"versionEndIncluding": "2.8.2.0000"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:bel_en:*:*:*",
"vulnerable": true,
"matchCriteriaId": "74A96C2D-0AE4-4E83-9B71-1EB851C2E720",
"versionEndIncluding": "2.8.3.0100"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:int_en:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C6B44E48-5EE4-4490-A970-D20248509D12",
"versionEndIncluding": "2.8.4.0300"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:esp:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B21D31C7-EE0E-4A0B-AE3E-373F94B6E248",
"versionEndIncluding": "2.8.5.0200"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:pt:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4BF53F49-DEBD-4FE5-87D9-74BF6D50AC55",
"versionEndIncluding": "2.8.7.0100"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:bel_fr:*:*:*",
"vulnerable": true,
"matchCriteriaId": "ED8F7CF9-F7FC-46EF-8420-32E779333D88",
"versionEndIncluding": "2.8.8.0100"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}