CVE-2025-13844
CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.16%
- Percentil entre todas las CVEs puntuadas: 5
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution85 % - Impacto principal
T1059Command and Scripting Interpreterexecution75 %
Requiere interacción del usuario (UI:A) para importar archivo malicioso (.SSD). Double free causa corrupción de memoria que permite ejecución de código arbitrario en cliente Rapsody.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-415
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-13844",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-13844",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-01-15T18:55:20.238410Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.4,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "ACTIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "EcoStruxure Power Build Rapsody",
"versions": [
{
"status": "affected",
"version": "FR v2.8.1 and prior"
},
{
"status": "affected",
"version": "INT v2.8.6 and prior"
},
{
"status": "affected",
"version": "ES v2.8.5 and prior"
},
{
"status": "affected",
"version": "BEL (NL) v2.8.3 and prior"
},
{
"status": "affected",
"version": "BEL (FR) v2.8.8 and prior"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-01-15T19:16:02.747",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-04.pdf",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-415"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody."
},
{
"lang": "es",
"value": "CWE-415: Existe una vulnerabilidad de doble liberación (Double Free) que podría causar corrupción de memoria en el heap cuando el usuario final importa un archivo de proyecto malicioso (archivo SSD) compartido por el atacante en Rapsody."
}
],
"lastModified": "2026-09-03T03:15:21.897",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:fr:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B0F9F08A-DA7C-404C-B846-0439C1BB68C0",
"versionEndIncluding": "2.8.1"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:bel_nl:*:*:*",
"vulnerable": true,
"matchCriteriaId": "35A14DC6-6CAE-4ABA-812E-D60A5A556284",
"versionEndIncluding": "2.8.3"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:es:*:*:*",
"vulnerable": true,
"matchCriteriaId": "776BC34F-121F-4FE8-BE20-0A46433225AA",
"versionEndIncluding": "2.8.5"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:int:*:*:*",
"vulnerable": true,
"matchCriteriaId": "20D6437D-D54C-407D-A301-0F11AF975235",
"versionEndIncluding": "2.8.6"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:bel_fr:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2C0E74D9-8163-45EA-89C3-F103CFFDF427",
"versionEndIncluding": "2.8.8"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}