CVE-2025-11789
Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'DownloadFile' function converts a parameter to an integer using 'atoi()' and then uses it as an index in the 'FilesDownload' array with '(&FilesDownload)[iVar2]'. If the parameter is too large, it will access memory beyond the limits.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.26%
- Percentil entre todas las CVEs puntuadas: 17
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1005Data from Local Systemcollection70 %
Acceso remoto en red con autenticación (PR:L), lectura fuera de límites (CWE-125) permite acceder a memoria adyacente; la vulnerabilidad en función de descarga expone datos sin garantía de ejecución de código.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (2)
CWE
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-11789",
"cveTags": [
{
"tags": [
"unsupported-when-assigned"
],
"sourceIdentifier": "cve-coordination@incibe.es"
}
],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-11789",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-12-02T13:27:07.563850Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cve-coordination@incibe.es",
"affectedData": [
{
"vendor": "SGE-PLC1000 SGE-PLC50",
"product": "Circutor",
"versions": [
{
"status": "affected",
"version": "9.0.2"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-12-02T13:15:52.897",
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0",
"tags": [
"Third Party Advisory"
],
"source": "cve-coordination@incibe.es"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'DownloadFile' function converts a parameter to an integer using 'atoi()' and then uses it as an index in the 'FilesDownload' array with '(&FilesDownload)[iVar2]'. If the parameter is too large, it will access memory beyond the limits."
},
{
"lang": "es",
"value": "Vulnerabilidad de lectura fuera de límites en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. La función 'DownloadFile' convierte un parámetro a un entero usando 'atoi()' y luego lo usa como un índice en el array 'FilesDownload' con '(&FilesDownload)[iVar2]'. Si el parámetro es demasiado grande, accederá a memoria más allá de los límites."
}
],
"lastModified": "2026-09-25T23:10:00.463",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve-coordination@incibe.es"
}