CVE-2025-10685
Heap-based buffer overflow vulnerability in Softing Industrial Automation GmbH smartLink SW-PN and smartLink SW-HT (Webserver modules) allows overflow buffers.This issue affects:
smartLink SW-PN: through 1.03
smartLink SW-HT: through 1.42
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:A/V:X/RE:L/U:Red
- Puntuación base: 7.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.49%
- Percentil entre todas las CVEs puntuadas: 40
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access85 % - Impacto principal
T1059Command and Scripting Interpreterexecution75 % - Impacto secundario
T1499.004Application or System Exploitationimpact65 %
Heap buffer overflow en módulo web accesible por red sin autenticación (AV:N, PR:N, UI:N) permite ejecución de código arbitrario o DoS; CWE-122 típicamente permite RCE. VA:H y SA:H confirman impacto crítico.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (2)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-122
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-10685",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-10685",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-03-16T14:41:54.340261Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "AUTOMATIC",
"baseScore": 7.7,
"Automatable": "YES",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:A/V:X/RE:L/U:Red",
"exploitMaturity": "UNREPORTED",
"providerUrgency": "RED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "LOW",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"affectedData": [
{
"vendor": "Softing",
"modules": [
"Webserver"
],
"product": "smartLink SW-PN",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.03"
},
{
"status": "unaffected",
"version": "1.04",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Softing",
"modules": [
"Webserver"
],
"product": "smartLink SW-HT",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.42"
},
{
"status": "unaffected",
"version": "1.43",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-03-16T14:17:53.890",
"references": [
{
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10685.html",
"source": "10de8ef9-5c89-4b17-8228-e97b74acf4bd"
},
{
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10685.json",
"source": "10de8ef9-5c89-4b17-8228-e97b74acf4bd"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"description": [
{
"lang": "en",
"value": "CWE-122"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Heap-based buffer overflow vulnerability in Softing Industrial Automation GmbH smartLink SW-PN and smartLink SW-HT (Webserver modules) allows overflow buffers.This issue affects:\n\nsmartLink SW-PN: through 1.03\n\nsmartLink SW-HT: through 1.42"
},
{
"lang": "es",
"value": "Vulnerabilidad de desbordamiento de búfer basado en montículo en Softing Industrial Automation GmbH smartLink SW-PN y smartLink SW-HT (módulos de servidor web) permite el desbordamiento de búferes. Este problema afecta a:\n\nsmartLink SW-PN: hasta 1.03\n\nsmartLink SW-HT: hasta 1.42"
}
],
"lastModified": "2026-06-17T08:28:46.020",