CVE-2025-10151
Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.This issue affects
smartLink HW-PN: from 1.02 through 1.03
smartLink HW-DP: 1.31
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:X/RE:M/U:Amber
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.23%
- Percentil entre todas las CVEs puntuadas: 13
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1499.004Application or System Exploitationimpact65 %
CWE-667 (improper locking) en gateway remoto con PR:L permite ataque DoS por agotamiento de recursos o corrupción de memoria con acceso autenticado a red adyacente; AV:N/PR:L/AC:L indica T1210.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (2)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-667
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-10151",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-10151",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-10-28T13:23:50.979355Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "USER",
"baseScore": 7.2,
"Automatable": "YES",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:X/RE:M/U:Amber",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "AMBER",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "LOW",
"subIntegrityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"vulnAvailabilityImpact": "LOW",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "MODERATE",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"affectedData": [
{
"vendor": "Softing Industrial Automation GmbH",
"product": "smartLink HW-PN",
"versions": [
{
"status": "affected",
"version": "1.02",
"versionType": "custom",
"lessThanOrEqual": "1.03"
}
],
"defaultStatus": "affected"
},
{
"vendor": "Softing Industrial Automation GmbH",
"product": "smartLink HW-DP",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.31"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-10-28T08:15:32.917",
"references": [
{
"url": "https://https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10151.html",
"source": "10de8ef9-5c89-4b17-8228-e97b74acf4bd"
},
{
"url": "https://https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10151.json",
"source": "10de8ef9-5c89-4b17-8228-e97b74acf4bd"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"description": [
{
"lang": "en",
"value": "CWE-667"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.This issue affects\n\nsmartLink HW-PN: from 1.02 through 1.03\n\nsmartLink HW-DP: 1.31"
}
],
"lastModified": "2026-06-17T08:27:47.270",
"sourceIdentifier": "10de8ef9-5c89-4b17-8228-e97b74acf4bd"
}