« Volver al listado

CVE-2025-0556

Estado: AnalizadaMedia (6.5)—

In Progress® Telerik® Report Server, versions prior to 2025 Q1 (11.0.25.211) when using the older .NET Framework implementation, communication of non-sensitive information between the service agent process and app host process occurs over an unencrypted tunnel, which can be subjected to local network traffic sniffing.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-0556",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-0556",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-02-12T15:33:21.152666Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "security@progress.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "security@progress.com",
      "affectedData": [
        {
          "vendor": "Progress Software",
          "modules": [
            ".NET Framework Implementation"
          ],
          "product": "Telerik Report Server",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0",
              "lessThan": "2025 Q1 (11.0.25.211)",
              "versionType": "custom"
            }
          ],
          "platforms": [
            "Windows"
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-02-12T16:15:43.030",
  "references": [
    {
      "url": "https://docs.telerik.com/report-server/knowledge-base/kb-security-cleartext-transmission-cve-2025-0556",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security@progress.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "security@progress.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-319"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Progress® Telerik® Report Server, versions prior to 2025 Q1 (11.0.25.211) when using the older .NET Framework implementation, communication of non-sensitive information between the service agent process and app host process occurs over an unencrypted tunnel, which can be subjected to local network traffic sniffing."
    },
    {
      "lang": "es",
      "value": "En Progress® Telerik® Report Server, versiones anteriores a 2025 Q1 (11.0.25.211) cuando se utiliza la implementación .NET framework más antigua, la comunicación de información no confidencial entre el proceso del agente de servicio y el proceso del host de la aplicación se produce a través de un túnel no cifrado, que puede estar sujeto al rastreo del tráfico de la red local."
    }
  ],
  "lastModified": "2026-06-17T08:26:41.970",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:progress:telerik_report_server:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "F55B3697-23F9-491C-BD14-2841CD76109A",
              "versionEndExcluding": "11.0.25.211"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security@progress.com"
}