CVE-2025-0416
Local privilege escalation through insecure DCOM configuration in Valmet DNA versions prior to C2023. The DCOM object Valmet DNA Engineering has permissions that allow it to run commands as a user with the SeImpersonatePrivilege privilege. The SeImpersonatePrivilege privilege is a Windows permission that allows a process to impersonate another user. An attacker can use this vulnerability to escalate their privileges and take complete control of the system.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:Y/R:U/V:D/RE:H/U:Amber
- Puntuación base: 8.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.21%
- Percentil entre todas las CVEs puntuadas: 10
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement60 % - Impacto principal
T1068Exploitation for Privilege Escalationprivilege escalation55 %
Inferido por reglas deterministas a partir del vector CVSS y la CWE. Solo orientativo.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-250
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-0416",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-0416",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-04-01T14:03:57.457938Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "db4dfee8-a97e-4877-bfae-eba6d14a2166",
"cvssData": {
"Safety": "NEGLIGIBLE",
"version": "4.0",
"Recovery": "USER",
"baseScore": 8.9,
"Automatable": "YES",
"attackVector": "ADJACENT",
"baseSeverity": "HIGH",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:Y/R:U/V:D/RE:H/U:Amber",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "AMBER",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "LOW",
"subIntegrityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "HIGH",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "db4dfee8-a97e-4877-bfae-eba6d14a2166",
"affectedData": [
{
"vendor": "Valmet",
"product": "Valmet DNA",
"versions": [
{
"status": "affected",
"version": "C2007",
"versionType": "custom",
"lessThanOrEqual": "C2022"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-04-01T04:15:37.727",
"references": [
{
"url": "https://www.valmet.com/about-us/about/research-and-development/vulnerabilityadvisories/cve-2025-0416/",
"source": "db4dfee8-a97e-4877-bfae-eba6d14a2166"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "db4dfee8-a97e-4877-bfae-eba6d14a2166",
"description": [
{
"lang": "en",
"value": "CWE-250"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Local privilege escalation through insecure DCOM configuration in Valmet DNA versions prior to C2023. The DCOM object Valmet DNA Engineering has permissions that allow it to run commands as a user with the SeImpersonatePrivilege privilege. The SeImpersonatePrivilege privilege is a Windows permission that allows a process to impersonate another user. An attacker can use this vulnerability to escalate their privileges and take complete control of the system."
},
{
"lang": "es",
"value": "Escalada de privilegios locales mediante una configuración DCOM insegura en versiones de Valmet DNA anteriores a C2023. El objeto DCOM Valmet DNA Engineering tiene permisos que le permiten ejecutar comandos como un usuario con el privilegio SeImpersonatePrivilege. Este privilegio es un permiso de Windows que permite a un proceso suplantar la identidad de otro usuario. Un atacante puede aprovechar esta vulnerabilidad para escalar sus privilegios y tomar el control total del sistema."
}
],
"lastModified": "2026-08-26T14:17:06.393",
"sourceIdentifier": "db4dfee8-a97e-4877-bfae-eba6d14a2166"
}