CVE-2024-9832
There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to device settings that could disrupt the function of the device and/or result in unauthorized information disclosure.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
- Puntuación base: 9.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.18%
- Percentil entre todas las CVEs puntuadas: 7
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation65 % - Impacto secundario
T1005Data from Local Systemcollection60 % - Impacto secundario
T1565.001Stored Data Manipulationimpact70 %
Acceso local sin interacción (AV:L/UI:N) permite fuerza bruta contra credenciales clínicas. Logro: acceso no autorizado (T1078.001), manipulación de configuración del dispositivo (T1565.001) y lectura de datos médicos (T1005).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-307
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-9832",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-9832",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-11-18T15:36:22.221928Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productsecurity@baxter.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 9.3,
"attackVector": "LOCAL",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 2.5
}
]
},
"affected": [
{
"source": "productsecurity@baxter.com",
"affectedData": [
{
"vendor": "Baxter",
"product": "Life2000 Ventilation System",
"versions": [
{
"status": "affected",
"version": "06.08.00.00 and prior"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:baxter:life2000_ventilator_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "baxter",
"product": "life2000_ventilator_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "06.08.00.00"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2024-11-14T21:15:22.593",
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-319-01",
"source": "productsecurity@baxter.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "productsecurity@baxter.com",
"description": [
{
"lang": "en",
"value": "CWE-307"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to device settings that could disrupt the function of the device and/or result in unauthorized information disclosure."
},
{
"lang": "es",
"value": "No existe límite en la cantidad de intentos fallidos de inicio de sesión permitidos con la contraseña del médico o la contraseña del médico con número de serie. Un atacante podría ejecutar un ataque de fuerza bruta para obtener acceso no autorizado al respirador y luego realizar cambios en la configuración del dispositivo que podrían interrumpir el funcionamiento del dispositivo o dar como resultado la divulgación no autorizada de información."
}
],
"lastModified": "2026-06-17T08:25:21.120",
"sourceIdentifier": "productsecurity@baxter.com"
}