« Volver al listado

CVE-2024-9764

Estado: AnalizadaAlta (7.8)—

Tungsten Automation Power PDF PDF File Parsing Use-After-Free Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.

The specific flaw exists within the parsing of PDF files. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24480.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Requiere interacción del usuario (UI:R) abriendo archivo PDF malicioso; use-after-free permite ejecución de código arbitrario en el contexto del proceso.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-9764",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-9764",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-25T15:09:28.578198Z"
        }
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "zdi-disclosures@trendmicro.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "affectedData": [
        {
          "vendor": "Tungsten Automation",
          "product": "Power PDF",
          "versions": [
            {
              "status": "affected",
              "version": "5.0.0.10.0.23307"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:tungstenautomation:power_pdf:*:*:*:*:*:*:*:*"
          ],
          "vendor": "tungstenautomation",
          "product": "power_pdf",
          "versions": [
            {
              "status": "affected",
              "version": "5.0.0.10.0.23307",
              "lessThan": "5.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-11-22T21:15:30.500",
  "references": [
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1362/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "zdi-disclosures@trendmicro.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "zdi-disclosures@trendmicro.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-416"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tungsten Automation Power PDF PDF File Parsing Use-After-Free Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of PDF files. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24480."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de ejecución remota de código después de la liberación del análisis de archivos PDF de Tungsten Automation Power PDF. Esta vulnerabilidad permite a atacantes remotos ejecutar código arbitrario en las instalaciones afectadas de Tungsten Automation Power PDF. Se requiere la interacción del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una página maliciosa o abrir un archivo malicioso. La falla específica existe en el análisis de archivos PDF. El problema es el resultado de la falta de validación de la existencia de un objeto antes de realizar operaciones en el objeto. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual. Era ZDI-CAN-24480."
    }
  ],
  "lastModified": "2026-06-17T08:25:12.870",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:tungstenautomation:power_pdf:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "07AF31C9-62C2-4FCA-975B-EEFCF34B8C78",
              "versionEndExcluding": "5.1"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com"
}