Status: AnalyzedHigh (8.3)—

Multiple SQL Injection vulnerabilities exist in the reporting application. A user with advanced report application access rights can exploit the SQL injection, allowing them to execute commands on the underlying operating system with elevated privileges.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

🎯 ATT&CK techniques

How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.

SQL injection (CWE-89) en aplicación de reporting con acceso autenticado (PR:L) permite ejecución de comandos del sistema operativo con privilegios elevados. AV:N indica explotación remota.

Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.

🛡️ ATT&CK mitigations that cover these techniques

Affected technologies (1)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2024-9134",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-9134",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-01-13T20:13:52.238229Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "psirt@arista.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.3,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.5,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@arista.com",
      "affectedData": [
        {
          "vendor": "Arista Networks",
          "product": "Arista Edge Threat Management",
          "versions": [
            {
              "status": "affected",
              "version": "17.1.0",
              "versionType": "custom",
              "lessThanOrEqual": "17.1.1"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-01-10T22:15:27.033",
  "references": [
    {
      "url": "https://www.arista.com/en/support/advisories-notices/security-advisory/20454-security-advisory-0105",
      "tags": [
        "Exploit",
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "psirt@arista.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "psirt@arista.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple SQL Injection vulnerabilities exist in the reporting application.  A user with advanced report application access rights can exploit the SQL injection, allowing them to execute commands on the underlying operating system with elevated privileges."
    },
    {
      "lang": "es",
      "value": "Existen múltiples vulnerabilidades de inyección SQL en la aplicación de informes. Un usuario con derechos de acceso avanzados a la aplicación de informes puede aprovechar la inyección SQL, lo que le permitirá ejecutar comandos en el sistema operativo subyacente con privilegios elevados."
    }
  ],
  "lastModified": "2026-06-17T08:24:01.213",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:arista:ng_firewall:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E48E6FC7-9C47-4334-96C7-D4418610C021",
              "versionEndExcluding": "17.2"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "psirt@arista.com"
}