CVE-2024-8933
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of confidentiality and integrity of controllers. To be successful, the attacker needs to inject themself inside the logical network while a valid user uploads or downloads a project file into the controller.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.29%
- Percentil entre todas las CVEs puntuadas: 20
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution60 %
Inferido por reglas deterministas a partir del vector CVSS y la CWE. Solo orientativo.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
CWE
- CWE-924
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-8933",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-8933",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-11-13T15:32:16.482241Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.6
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.5,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "ACTIVE",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "Modicon M340 CPU (part numbers BMXP34*)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Modicon MC80 (part numbers BMKC80)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Modicon Momentum Unity M1E Processor (171CBU*)",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*"
],
"vendor": "schneider-electric",
"product": "modicon_m340",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:h:schneider-electric:modicon_mc80:-:*:*:*:*:*:*:*"
],
"vendor": "schneider-electric",
"product": "modicon_mc80",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:h:schneider-electric:modicon_momentum_unity_m1e_processor:-:*:*:*:*:*:*:*"
],
"vendor": "schneider-electric",
"product": "modicon_momentum_unity_m1e_processor",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-11-13T04:15:05.037",
"references": [
{
"url": "https://download.schneider-electric.com/doc/SEVD-2024-317-02/SEVD-2024-317-02.pdf",
"source": "cybersecurity@se.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-924"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel\nvulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of\nconfidentiality and integrity of controllers. To be successful, the attacker needs to inject themself inside the\nlogical network while a valid user uploads or downloads a project file into the controller."
},
{
"lang": "es",
"value": "CWE-924: Existe una vulnerabilidad de aplicación inadecuada de la integridad de los mensajes durante la transmisión en un canal de comunicación que podría provocar la recuperación del hash de la contraseña, lo que podría provocar la denegación del servicio y la pérdida de confidencialidad e integridad de los controladores. Para tener éxito, el atacante debe inyectarse dentro de la red lógica mientras un usuario válido carga o descarga un archivo de proyecto en el controlador."
}
],
"lastModified": "2026-06-17T08:23:35.027",
"sourceIdentifier": "cybersecurity@se.com"
}