CVE-2024-8422
CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when application user opens a malicious Zelio Soft 2 project file.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.21%
- Percentil entre todas las CVEs puntuadas: 10
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution95 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 % - Impacto secundario
T1499.004Application or System Exploitationimpact75 %
Use-after-free al abrir archivo malicioso requiere UI:R (interacción usuario). Impacto: ejecución de código arbitrario (T1059) y negación de servicio (T1499.004 - crash de aplicación).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-416
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-8422",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-8422",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-10-08T12:43:43.813201Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "Zelio Soft 2",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.4.2.2"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:schneider-electric:zelio_soft_2:*:*:*:*:*:*:*:*"
],
"vendor": "schneider-electric",
"product": "zelio_soft_2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "5.4.2.2",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-10-08T10:15:04.880",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-282-06.pdf",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-416"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial\nof service and loss of confidentiality & integrity when application user opens a malicious Zelio\nSoft 2 project file."
},
{
"lang": "es",
"value": "CWE-416: Existe una vulnerabilidad de Use After Free que podría provocar la ejecución de código arbitrario, denegación de servicio y pérdida de confidencialidad e integridad cuando el usuario de la aplicación abre un archivo de proyecto malicioso de Zelio Soft 2."
}
],
"lastModified": "2026-06-17T08:22:33.153",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:zelio_soft_2:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DEC48CCF-0061-467A-BF3C-CAD9364C2BBD",
"versionEndExcluding": "5.4.2.2"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}