CVE-2024-7986

Medium (6.8)—
Routine follow-upSeverity Medium 6.8. No public exploit or active exploitation known.
Severity6.8Medium · CVSS 4.0
Exploitation probability0.58 %higher than 41% of CVEs · score from Nov 25, 2026
Active exploitationNonot in the CISA catalog · checked Nov 25, 05:00 PM
Public exploitNot knownno public code found

A vulnerability exists in the Rockwell Automation ThinManager® ThinServer that allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer™ service to read arbitrary files by creating a junction that points to the target directory.

Timeline

Built from our own data: NVD, CISA KEV and other exploitation catalogues, FIRST EPSS, public exploits, specialised media and Orbitaley coverage.

  1. CVE record published in NVD
  2. Record last modified in NVD

Affected technologies (1)

NVD record

NVD status
Analyzed
Published
Aug 23, 2024
Last modified
Jun 17, 2026
CVSS vector
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Weakness (CWE)
CWE-732

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2024-7986",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-7986",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-08-28T16:20:54.169556Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "PSIRT@rockwellautomation.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 6.8,
          "Automatable": "NOT_DEFINED",
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "PSIRT@rockwellautomation.com",
      "affectedData": [
        {
          "vendor": "Rockwell Automation",
          "product": "ThinManager® ThinServer™",
          "versions": [
            {
              "status": "affected",
              "version": "11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2024-08-23T12:15:03.920",
  "references": [
    {
      "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1692.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "PSIRT@rockwellautomation.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "PSIRT@rockwellautomation.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability exists in the Rockwell Automation ThinManager® ThinServer that allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer™ service to read arbitrary files by creating a junction that points to the target directory."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad en Rockwell Automation ThinManager® ThinServer que permite a un actor de amenazas revelar información confidencial. Un actor de amenazas puede explotar esta vulnerabilidad abusando del servicio ThinServer™ para leer archivos arbitrarios creando una unión que apunte al directorio de destino."
    }
  ],
  "lastModified": "2026-06-17T08:21:37.187",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2BC59B57-F8F5-4979-826B-EAA0A8456B2A",
              "versionEndExcluding": "11.1.8",
              "versionStartIncluding": "11.1.0"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "79481998-C98B-4486-A2DC-C4DE324DCA10",
              "versionEndExcluding": "11.2.9",
              "versionStartIncluding": "11.2.0"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BFD553E2-EB04-4D97-AD70-2175933E3DCD",
              "versionEndExcluding": "12.0.7",
              "versionStartIncluding": "12.0.0"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FC5BBCD2-0C47-4B48-81DD-D56D5677BFA0",
              "versionEndExcluding": "12.1.8",
              "versionStartIncluding": "12.1.0"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7EEDB253-45FB-4722-994A-E0EF00C7F405",
              "versionEndExcluding": "13.0.5",
              "versionStartIncluding": "13.0.0"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "F2FB9C58-1AAF-46CB-BBB5-909223EE5572",
              "versionEndExcluding": "13.1.3",
              "versionStartIncluding": "13.1.0"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BB3AA59A-9CA4-4CD0-981C-B974A94BAC30",
              "versionEndExcluding": "13.2.2",
              "versionStartIncluding": "13.2.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "PSIRT@rockwellautomation.com"
}