« Volver al listado

CVE-2024-7697

Estado: AnalizadaAlta (7.5)—

Logical vulnerability in the mobile application (com.transsion.carlcare) may lead to user information leakage risks.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-7697",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-7697",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-08-12T14:08:51.191706Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      },
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea",
      "affectedData": [
        {
          "vendor": "TECNO",
          "product": "com.transsion.carlcare",
          "versions": [
            {
              "status": "affected",
              "version": "5.9.5"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:tecno:com.transsion.carlcare:5.9.5:*:*:*:*:*:*:*"
          ],
          "vendor": "tecno",
          "product": "com.transsion.carlcare",
          "versions": [
            {
              "status": "affected",
              "version": "5.9.5"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-08-12T13:38:58.913",
  "references": [
    {
      "url": "https://security.tecno.com/SRC/blogdetail/294?lang=en_US",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea"
    },
    {
      "url": "https://security.tecno.com/SRC/securityUpdates?type=SA",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea",
      "description": [
        {
          "lang": "en",
          "value": "CWE-359"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Logical vulnerability in the mobile application (com.transsion.carlcare) may lead to user information leakage risks."
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad lógica en la aplicación móvil (com.transsion.carlcare) puede generar riesgos de fuga de información del usuario."
    }
  ],
  "lastModified": "2026-06-17T08:20:44.630",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:transsion:carlcare:5.9.5:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "62BC0308-86B9-4C2D-BB2E-54D7D87FFC17"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea"
}