CVE-2024-7517
A command injection vulnerability in Brocade Fabric OS before 9.2.0c, and 9.2.1 through 9.2.1a on IP extension platforms could allow a local authenticated attacker to perform a privileged escalation via crafted use of the portcfg command.
This specific exploitation is only possible on IP Extension platforms: Brocade 7810, Brocade 7840, Brocade 7850 and on Brocade X6 or X7 directors with an SX-6 Extension blade installed. The attacker must be logged into the switch via SSH or serial console to conduct the attack.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.62%
- Percentil entre todas las CVEs puntuadas: 48
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation95 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 %
CWE-78 (command injection) en acceso local autenticado (AV:L, PR:L) sin interacción permite escalada de privilegios. El ataque se ejecuta via portcfg command en IP extension platforms.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-7517",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-7517",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-11-21T14:02:36.321972Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "sirt@brocade.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.5,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "sirt@brocade.com",
"affectedData": [
{
"vendor": "Brocade",
"product": "Fabric OS",
"versions": [
{
"status": "affected",
"version": "Brocade Fabric OS versions before 9.2.0c, and 9.2.1 through 9.2.1a"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:brocade:fabric_os:-:*:*:*:*:*:*:*"
],
"vendor": "brocade",
"product": "fabric_os",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "9.2.0c",
"versionType": "custom"
},
{
"status": "affected",
"version": "9.2.1",
"lessThan": "9.2.1a",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-11-21T11:15:35.990",
"references": [
{
"url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/25071",
"tags": [
"Third Party Advisory"
],
"source": "sirt@brocade.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "sirt@brocade.com",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A command injection vulnerability in Brocade Fabric OS before 9.2.0c, and 9.2.1 through 9.2.1a on IP extension platforms could allow a local authenticated attacker to perform a privileged escalation via crafted use of the portcfg command.\n\nThis specific exploitation is only possible on IP Extension platforms: Brocade 7810, Brocade 7840, Brocade 7850 and on Brocade X6 or X7 directors with an SX-6 Extension blade installed. The attacker must be logged into the switch via SSH or serial console to conduct the attack."
},
{
"lang": "es",
"value": "Una vulnerabilidad de inyección de comandos en Brocade Fabric OS anterior a la versión 9.2.0c y de la 9.2.1 a la 9.2.1a en plataformas de extensión IP podría permitir que un atacante autenticado local realice una escalada de privilegios mediante el uso manipulado del comando portcfg. Esta explotación específica solo es posible en plataformas de extensión IP: Brocade 7810, Brocade 7840, Brocade 7850 y en directores Brocade X6 o X7 con un blade de extensión SX-6 instalado. El atacante debe iniciar sesión en el conmutador a través de SSH o una consola serial para realizar el ataque."
}
],
"lastModified": "2026-06-17T08:20:21.510",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CBBBE7D4-4F32-4B91-99EB-85DB773527F1",
"versionEndIncluding": "9.2.0c"
},
{
"criteria": "cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "26C81385-ABE1-4894-A63E-27DCA08B363D",
"versionEndIncluding": "9.2.1a",
"versionStartIncluding": "9.2.1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "sirt@brocade.com"
}