CVE-2024-6795
Estado: AnalizadaCrítica (9.8)—
In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database.
An attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content
and/or perform administrative operations including shutting down the database.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.60%
- Percentil entre todas las CVEs puntuadas: 47
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-89
- CWE-89
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-6795",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-6795",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-09-09T20:04:42.779977Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productsecurity@baxter.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 10,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "productsecurity@baxter.com",
"affectedData": [
{
"vendor": "Baxter",
"product": "Connex Health Portal",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "8/30/2024",
"versionType": "date"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:hillrom:connex_health_portal:*:*:*:*:*:*:*:*"
],
"vendor": "hillrom",
"product": "connex_health_portal",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "8.30.2024",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2024-09-09T20:15:05.253",
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "productsecurity@baxter.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productsecurity@baxter.com",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database. \n\nAn attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content \n\nand/or perform administrative operations including shutting down the database."
},
{
"lang": "es",
"value": "En el portal de salud Connex publicado antes del 30/8/2024, se encontraron vulnerabilidades de inyección SQL que podrían haber permitido que un atacante no autenticado obtuviera acceso no autorizado a la base de datos del portal Connex. Un atacante podría haber enviado un payload manipulado al portal Connex que podría haber dado lugar a la modificación y divulgación del contenido de la base de datos y/o a la realización de operaciones administrativas, incluido el cierre de la base de datos."
}
],
"lastModified": "2026-06-17T08:18:43.797",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:baxter:connex_health_portal:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "21E3F634-BFB7-4605-91ED-E03F8EA2E7C4",
"versionEndExcluding": "2024-08-30"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productsecurity@baxter.com"
}