CVE-2024-6596
Estado: AnalizadaCrítica (9.8)—
An unauthenticated remote attacker can run malicious c# code included in curve files and execute commands in the users context.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.79%
- Percentil entre todas las CVEs puntuadas: 55
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (6)
CWE
- CWE-94
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-6596",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-6596",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-09-10T16:14:52.325432Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "info@cert.vde.com",
"affectedData": [
{
"vendor": "Endress+Hauser",
"product": "Echo Curve Viewer",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "5.2.2.6"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Endress+Hauser",
"product": "FieldCare SFE500 Package USB",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "V1.40.00.7448"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Endress+Hauser",
"product": "FieldCare SFE500 Package Web-Package",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "V1.40.00.7448"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Endress+Hauser",
"product": "Field Xpert SMT50",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "SMT50_Win10_LTSC_21H2_v1.07.00_RC02_03"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Endress+Hauser",
"product": "Field Xpert SMT70",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "SMT70_Win10_LTSC_21H2_v1.07.00_RC02_01"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Endress+Hauser",
"product": "Field Xpert SMT77",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "SMT77_Win10_SAC_22H2_v1.08.04_RC03_02"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Endress+Hauser",
"product": "Field Xpert SMT79",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "V1.08.02-1.8.8684.34292"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:endress\\+hauser:echo_curve_viewer_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "endress\\+hauser",
"product": "echo_curve_viewer_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "5.2.2.6"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:o:endress\\+hauser:fieldcare_sfe500_package_usb_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "endress\\+hauser",
"product": "fieldcare_sfe500_package_usb_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "1.40.00.7448"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:o:endress\\+hauser:fieldcare_sfe500_package_web-package_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "endress\\+hauser",
"product": "fieldcare_sfe500_package_web-package_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "1.40.00.7448"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:o:endress\\+hauser:field_xpert_smt70_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "endress\\+hauser",
"product": "field_xpert_smt70_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "SMT70_Win10_LTSC_21H2_v1.07.00_RC02_01"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:o:endress\\+hauser:field_xpert_smt50_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "endress\\+hauser",
"product": "field_xpert_smt50_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "SMT50_Win10_LTSC_21H2_v1.07.00_RC02_03"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:o:endress\\+hauser:field_xpert_smt77_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "endress\\+hauser",
"product": "field_xpert_smt77_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "SMT77_Win10_SAC_22H2_v1.08.04_RC03_02"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:o:endress\\+hauser:field_xpert_smt79_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "endress\\+hauser",
"product": "field_xpert_smt79_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "1.08.02-1.8.8684.34292"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-09-10T08:15:03.350",
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-041",
"tags": [
"Third Party Advisory"
],
"source": "info@cert.vde.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"description": [
{
"lang": "en",
"value": "CWE-94"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated remote attacker can run malicious c# code included in curve files and execute commands in the users context."
},
{
"lang": "es",
"value": "Un atacante remoto no autenticado puede ejecutar código C# malicioso incluido en archivos de curva y ejecutar comandos en el contexto de los usuarios."
}
],
"lastModified": "2026-06-17T08:18:18.810",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:endress:echo_curve_viewer:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "086D71F2-A7F5-48DC-8BF2-BDDF337AFD74",
"versionEndExcluding": "6.0.0"
},
{
"criteria": "cpe:2.3:a:endress:fieldcare_sfe500_package:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EB7DDCFA-E0C7-401B-89B2-48A61CF28020",
"versionEndExcluding": "1.40.1"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:endress:field_xpert_smt79_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1ECC6E57-9FD0-4106-8C9F-C17AE827F8C8"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:endress:field_xpert_smt79:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "BC7856B2-75C6-40E1-B36B-5FE0F6CF1B03"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:endress:field_xpert_smt77_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "16F7E7E7-C221-4498-B286-E029CF4EAFDD"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:endress:field_xpert_smt77:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "22CAA382-7A0F-4C46-B7F2-873BCB2D7C16"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:endress:field_xpert_smt70_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4105E9FA-0192-4247-A876-F522EB3743C5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:endress:field_xpert_smt70:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "2E2D48C9-563F-4F90-9D93-E31F746305E1"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:endress:field_xpert_smt50_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9BB5DE59-7030-4CA6-8749-EADA19A374FE"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:endress:field_xpert_smt50:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "36A029E4-3C6E-4106-A80D-FD6B0A1CD8CA"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "info@cert.vde.com"
}