CVE-2024-6403
Estado: ModificadaAlta (7.1)—
A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.99%
- Percentil entre todas las CVEs puntuadas: 61
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-121
- CWE-787
Referencias
- https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md
- https://vuldb.com/?ctiid.269948
- https://vuldb.com/?id.269948
- https://vuldb.com/?submit.360752
- https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md
- https://vuldb.com/?ctiid.269948
- https://vuldb.com/?id.269948
- https://vuldb.com/?submit.360752
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-6403",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-6403",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-07-02T19:38:09.935913Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 6.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"authentication": "SINGLE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 6.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Tenda",
"product": "A301",
"versions": [
{
"status": "affected",
"version": "15.13.08.12"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:tenda:a301_firmware:15.13.08.12:*:*:*:*:*:*:*"
],
"vendor": "tenda",
"product": "a301_firmware",
"versions": [
{
"status": "affected",
"version": "15.13.08.12"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-06-28T17:15:04.140",
"references": [
{
"url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.269948",
"tags": [
"Permissions Required"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.269948",
"tags": [
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.360752",
"tags": [
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?ctiid.269948",
"tags": [
"Permissions Required"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?id.269948",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?submit.360752",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Una vulnerabilidad fue encontrada en Tenda A301 15.13.08.12 y clasificada como crítica. La función formWifiBasicSet del archivo /goform/SetOnlineDevName es afectada por esta vulnerabilidad. La manipulación del argumento devName provoca un desbordamiento del búfer basado en pila. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador de esta vulnerabilidad es VDB-269948. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera."
}
],
"lastModified": "2026-06-17T08:17:56.753",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tendacn:a301_firmware:15.13.08.12:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C9D764F0-DC30-42AA-85BA-891AB544DD4D"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tendacn:a301:2.0:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0CF182E3-DCA1-45AC-AB73-E4CDFB7925C1"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}