CVE-2024-57964
Insecure Loading of Dynamic Link Libraries have been discovered in HVAC Energy Saving Program, which could allow local attackers to potentially disclose information or execute arbitray code on affected systems. This issue affects HVAC Energy Saving Program:.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.18%
- Percentil entre todas las CVEs puntuadas: 7
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution85 % - Impacto principal
T1574.007Path Interception by PATH Environment Variablestealth · execution80 % - Impacto secundario
T1059Command and Scripting Interpreterexecution75 %
AV:L UI:R indica ejecución en cliente (abrir archivo preparado). CWE-427 (DLL hijacking) + ejecución arbitraria = T1574.007 (secuestro DLL). AC:L C:H I:H A:H confirma impactos de ejecución de código.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-427
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-57964",
"cveTags": [
{
"tags": [
"unsupported-when-assigned"
],
"sourceIdentifier": "hirt@hitachi.co.jp"
}
],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-57964",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-02-18T15:50:48.506333Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "hirt@hitachi.co.jp",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.3
}
]
},
"affected": [
{
"source": "hirt@hitachi.co.jp",
"affectedData": [
{
"vendor": "Hitachi",
"product": "HVAC Energy Saving Program",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "*"
}
],
"defaultStatus": "affected"
}
]
}
],
"published": "2025-02-18T07:15:08.920",
"references": [
{
"url": "https://www.hitachi.com/hirt/hitachi-sec/2025/001.html",
"source": "hirt@hitachi.co.jp"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "hirt@hitachi.co.jp",
"description": [
{
"lang": "en",
"value": "CWE-427"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insecure Loading of Dynamic Link Libraries have been discovered in HVAC Energy Saving Program, which could allow local attackers to potentially disclose information or execute arbitray code on affected systems.\nThis issue affects HVAC Energy Saving Program:."
},
{
"lang": "es",
"value": "Se ha descubierto una carga insegura de librerías de vínculos dinámicos en HVAC Energy Saving Program, lo que podría permitir a atacantes locales divulgar información o ejecutar código arbitrario en los sistemas afectados. Este problema afecta al programa de ahorro de energía HVAC:"
}
],
"lastModified": "2026-06-17T08:14:19.993",
"sourceIdentifier": "hirt@hitachi.co.jp"
}