« Back to list

CVE-2024-57061

Status: DeferredCritical (9.8)—

An issue in Termius Version 9.9.0 through v.9.16.0 allows a physically proximate attacker to execute arbitrary code via the insecure Electron Fuses configuration.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

🎯 ATT&CK techniques

How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.

Vector CVSS AV:N sugiere red sin privilegios (T1190), pero descripción menciona atacante 'physically proximate' y 'Electron Fuses' (acceso local). Ajuste a T1068 sería más preciso; se mantiene T1190 por vector, con baja confianza. Ejecución arbitraria de código confirmada por CWE-94 (Improper Contro

Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.

🛡️ ATT&CK mitigations that cover these techniques

Affected technologies (1)

⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2024-57061",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-57061",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-25T15:23:50.385533Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2025-03-19T19:15:43.377",
  "references": [
    {
      "url": "https://book.hacktricks.xyz/macos-hardening/macos-security-and-privilege-escalation/macos-proces-abuse/macos-electron-applications-injection",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://sha999.medium.com/cve-2024-57061-termius-insufficient-electron-fuses-configuration-limited-disclosure-ab00d0970159",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.electron.build/tutorials/adding-electron-fuses.html",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://sha999.medium.com/cve-2024-57061-termius-insufficient-electron-fuses-configuration-limited-disclosure-ab00d0970159",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue in Termius Version 9.9.0 through v.9.16.0 allows a physically proximate attacker to execute arbitrary code via the insecure Electron Fuses configuration."
    },
    {
      "lang": "es",
      "value": "Un problema en Termius versión 9.9.0 a v.9.16.0 permite que un atacante físicamente próximo ejecute código arbitrario a través de la configuración insegura de Electron Fuses."
    }
  ],
  "lastModified": "2026-06-17T08:13:15.207",
  "sourceIdentifier": "cve@mitre.org"
}