CVE-2024-54126
This vulnerability exists in the TP-Link Archer C50 due to improper signature verification mechanism in the firmware upgrade process at its web interface. An attacker with administrative privileges within the router’s Wi-Fi range could exploit this vulnerability by uploading and executing malicious firmware which could lead to complete compromise of the targeted device.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.15%
- Percentil entre todas las CVEs puntuadas: 3
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1553.006Code Signing Policy Modificationdefense impairment80 % - Impacto secundario
T1195.002Compromise Software Supply Chaininitial access75 %
Acceso red adyacente (AV:A) con privilegios administrativos (PR:H). Falla verificación de firma en actualización firmware permite ejecución maliciosa, impactando integridad del dispositivo y evasión de defensas del router.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-347, CWE-494
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-54126",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-54126",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-12-05T15:56:14.433573Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "vdisclose@cert-in.org.in",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.5,
"Automatable": "NOT_DEFINED",
"attackVector": "ADJACENT",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "HIGH",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "vdisclose@cert-in.org.in",
"affectedData": [
{
"vendor": "TP-Link",
"product": "Archer C50 Wireless Router",
"versions": [
{
"status": "affected",
"version": "<Archer C50(EU)_V4_ 240917"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:tp-link:archer_c50_firmware:c50\\(eu\\)_v4_240917:*:*:*:*:*:*:*"
],
"vendor": "tp-link",
"product": "archer_c50_firmware",
"versions": [
{
"status": "affected",
"version": "c50\\(eu\\)_v4_240917"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-12-05T13:15:09.290",
"references": [
{
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01&VLCODE=CIVN-2024-0354",
"source": "vdisclose@cert-in.org.in"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "vdisclose@cert-in.org.in",
"description": [
{
"lang": "en",
"value": "CWE-347"
},
{
"lang": "en",
"value": "CWE-494"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability exists in the TP-Link Archer C50 due to improper signature verification mechanism in the firmware upgrade process at its web interface. An attacker with administrative privileges within the router’s Wi-Fi range could exploit this vulnerability by uploading and executing malicious firmware which could lead to complete compromise of the targeted device."
},
{
"lang": "es",
"value": "Esta vulnerabilidad existe en el TP-Link Archer C50 debido a un mecanismo de verificación de firma incorrecto en el proceso de actualización de firmware en su interfaz web. Un atacante con privilegios administrativos dentro del rango de Wi-Fi del router podría aprovechar esta vulnerabilidad al cargar y ejecutar un firmware malicioso que podría provocar la vulneración total del dispositivo objetivo."
}
],
"lastModified": "2026-06-17T08:09:49.177",
"sourceIdentifier": "vdisclose@cert-in.org.in"
}