CVE-2024-53649
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80).
Read full descriptionShow less
Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices.
CVSS
- Version: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Base score: 7.1
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.62%
- Percentile among all scored CVEs: 48
- Score date: 10/5/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
🎯 ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1210Exploitation of Remote Serviceslateral movement85 % - Primary impact
T1005Data from Local Systemcollection90 % - Secondary impact
T1552Unsecured Credentialscredential access75 %
Acceso remoto autenticado (PR:L) a dispositivo industrial sin privilegios previos. Lectura arbitraria de archivos por falta de validación de rutas (CWE-552).
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
🛡️ ATT&CK mitigations that cover these techniques
Affected technologies (1)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
CWEs
- CWE-552
References
Raw JSON (NVD)
Show
{
"id": "CVE-2024-53649",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-53649",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-01-14T14:31:48.612161Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SIPROTEC 5 6MD84 (CP300)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 6MD85 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 6MD86 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 6MD89 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.68",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 6MU85 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7KE85 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SA82 (CP100)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V8.90",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SA82 (CP150)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SA86 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SA87 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SD82 (CP100)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V8.90",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SD82 (CP150)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SD86 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SD87 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SJ81 (CP100)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V8.90",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SJ81 (CP150)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SJ82 (CP100)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V8.90",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SJ82 (CP150)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SJ85 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SJ86 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SK82 (CP100)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V8.90",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SK82 (CP150)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SK85 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SL82 (CP100)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V8.90",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SL82 (CP150)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SL86 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SL87 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SS85 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7ST85 (CP300)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.68",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7ST86 (CP300)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SX82 (CP150)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SX85 (CP300)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7SY82 (CP150)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7UM85 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7UT82 (CP100)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V8.90",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7UT82 (CP150)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7UT85 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7UT86 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7UT87 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7VE85 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7VK87 (CP300)",
"versions": [
{
"status": "affected",
"version": "V7.80",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 7VU85 (CP300)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPROTEC 5 Compact 7SX800 (CP050)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V9.80",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-01-14T11:15:16.820",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-194557.html",
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-552"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIPROTEC 5 6MD84 (CP300) (Todas las versiones < V9.80), SIPROTEC 5 6MD85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (Todas las versiones >= V7.80), SIPROTEC 5 6MU85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SA82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SA86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SD82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SD86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SJ81 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SJ82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SJ82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SJ85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SK82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SK85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SL82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SL86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (Todas las versiones), SIPROTEC 5 7ST86 (CP300) (Todas las versiones < V9.80), SIPROTEC 5 7SX82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SX85 (CP300) (Todas las versiones < V9.80), SIPROTEC 5 7SY82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7UM85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7UT82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7UT85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (todas las versiones anteriores a V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (todas las versiones anteriores a V9.80). Los dispositivos afectados no limitan adecuadamente la ruta a la que se puede acceder a través de su servidor web. Esto podría permitir que un atacante remoto autenticado lea archivos arbitrarios del sistema de archivos de los dispositivos afectados."
}
],
"lastModified": "2026-06-17T08:09:03.997",
"sourceIdentifier": "productcert@siemens.com"
}