CVE-2024-53242
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.18%
- Percentil entre todas las CVEs puntuadas: 7
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution85 % - Impacto principal
T1059Command and Scripting Interpreterexecution75 %
Vector CVSS con UI:P (requiere interacción del usuario) + archivo especializado (WRL) = ejecución en el cliente. Out-of-bounds read permite RCE en el contexto del proceso.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (2)
CWE
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-53242",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-53242",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-12-10T15:17:17.154033Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.3,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V14.2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V14.2.0.14",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V14.3",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V14.3.0.12",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V2312",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2312.0008",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Tecnomatix Plant Simulation V2302",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2302.0016",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Tecnomatix Plant Simulation V2404",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2404.0005",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-12-10T14:30:46.700",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Teamcenter Visualization V14.2 (todas las versiones < V14.2.0.14), Teamcenter Visualization V14.3 (todas las versiones < V14.3.0.12), Teamcenter Visualization V2312 (todas las versiones < V2312.0008), Tecnomatix Plant Simulation V2302 (todas las versiones < V2302.0016), Tecnomatix Plant Simulation V2404 (todas las versiones < V2404.0005). Las aplicaciones afectadas contienen una lectura fuera de los límites más allá del final de una estructura asignada mientras se analizan archivos WRL especialmente manipulados. Esto podría permitir que un atacante ejecute código en el contexto del proceso actual. (ZDI-CAN-25206)"
}
],
"lastModified": "2026-06-17T08:08:41.090",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "30D67C7D-1BB0-4CA7-8FBE-6E87711C74AC",
"versionEndExcluding": "14.2.0.14",
"versionStartIncluding": "14.2"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6FCD0CB7-ABFB-495A-8A87-393FCB108080",
"versionEndExcluding": "14.3.0.12",
"versionStartIncluding": "14.3"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C932CD9A-2238-47C1-9FEE-899DBDE695F7",
"versionEndExcluding": "2312.0008",
"versionStartIncluding": "2312.0"
},
{
"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0182F0C6-A825-4C15-A6BA-4319331A488E",
"versionEndExcluding": "2302.0016",
"versionStartIncluding": "2302.0"
},
{
"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "25851CA7-FEEA-42CB-8957-7D90BB5DA14A",
"versionEndExcluding": "2404.0005",
"versionStartIncluding": "2404.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}