« Volver al listado

CVE-2024-51444

Estado: AnalizadaAlta (7.1)—

A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The application insufficiently validates user input for database read queries. This could allow an authenticated remote attacker to conduct an SQL injection attack that bypasses authorization controls and allows to download any data from the application's database.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

SQL injection en servicio remoto (CWE-89) con PR:L requiere autenticación remota previa. Impacto primario: lectura no autorizada de BD (T1005). Secundario especulativo: manipulación de datos si la inyección permite escritura, aunque el texto solo documenta descarga.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-51444",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-51444",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-05-13T19:03:11.780675Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.8
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 7.1,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "Polarion V2310",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Polarion V2404",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2404.4",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2025-05-13T10:15:21.340",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-162255.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The application insufficiently validates user input for database read queries. This could allow an authenticated remote attacker to conduct an SQL injection attack that bypasses authorization controls and allows to download any data from the application's database."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Polarion V2310 (todas las versiones) y Polarion V2404 (todas las versiones anteriores a V2404.4). La aplicación no valida adecuadamente la entrada del usuario para las consultas de lectura de la base de datos. Esto podría permitir que un atacante remoto autenticado realice un ataque de inyección SQL que eluda los controles de autorización y permita descargar cualquier dato de la base de datos de la aplicación."
    }
  ],
  "lastModified": "2026-06-17T08:05:43.367",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:polarion_alm:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E432D0F7-0E9B-46C7-9A07-CB4DC920C8AB",
              "versionEndExcluding": "2404.4",
              "versionStartIncluding": "2404.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:polarion_alm:2310.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9B380DBD-1890-4CDB-8EB7-0BB81219E904"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}