CVE-2024-50373
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.28%
- Percentil entre todas las CVEs puntuadas: 69
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access95 % - Impacto principal
T1059Command and Scripting Interpreterexecution95 % - Impacto secundario
T1068Exploitation for Privilege Escalationprivilege escalation85 %
CWE-78 en servicio de red sin autenticación (AV:N, PR:N, UI:N): T1190. OS command injection ejecuta comandos con privilegios root: T1059 + escalada implícita (T1068).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (3)
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-50373",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-50373",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-11-26T14:11:04.352815Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "prodsec@nozominetworks.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "prodsec@nozominetworks.com",
"affectedData": [
{
"vendor": "Advantech",
"product": "EKI-6333AC-2G",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "<= 1.6.3"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Advantech",
"product": "EKI-6333AC-2GD",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "<= 1.6.3"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Advantech",
"product": "EKI-6333AC-1GPO",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "<= 1.2.1"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "advantech",
"product": "eki-6333ac-2g_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.6.3"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "advantech",
"product": "eki-6333ac-2gd_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.6.3"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "advantech",
"product": "eki-6333ac-1gpo_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.2.1"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-11-26T11:22:06.930",
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50373",
"tags": [
"Third Party Advisory"
],
"source": "prodsec@nozominetworks.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "prodsec@nozominetworks.com",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"restore_config_from_utility\" operation."
},
{
"lang": "es",
"value": "Se descubrió una vulnerabilidad CWE-78 \"Neutralización incorrecta de elementos especiales utilizados en un comando del SO ('Inyección de comando del SO')\" que afecta a los siguientes dispositivos fabricados por Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) y EKI-6333AC-1GPO (<= v1.2.1). La vulnerabilidad puede ser explotada por usuarios remotos no autenticados capaces de interactuar con el servicio \"edgserver\" predeterminado habilitado en el punto de acceso y se ejecutan comandos maliciosos con privilegios de superusuario. No hay autenticación habilitada en el servicio y la fuente de la vulnerabilidad reside en el código de procesamiento asociado a la operación \"restore_config_from_utility\"."
}
],
"lastModified": "2026-06-17T08:04:19.870",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B5E027C8-2521-45FC-BABB-4A6E3341F883",
"versionEndExcluding": "1.6.5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:advantech:eki-6333ac-2g:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B3B63DF4-0184-4108-B48B-D31179104701"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "447F8AEB-2C7C-411A-893C-11C2F7588C82",
"versionEndExcluding": "1.6.5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:advantech:eki-6333ac-2gd:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "02F70DBA-2D4C-4407-885D-71887A1A7979"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "828B9D05-0064-4690-A624-D3BF659BD316",
"versionEndExcluding": "1.2.2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:advantech:eki-6333ac-1gpo:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D2A73A2B-9FD5-4971-8FFF-1BA14BCCB37B"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "prodsec@nozominetworks.com"
}