« Back to list

CVE-2024-50358

Status: AnalyzedHigh (7.2)—

A CWE-15 "External Control of System or Configuration Setting" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

🎯 ATT&CK techniques

How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.

Acceso remoto por usuario autenticado (PR:H) sin interacción, con impactos de confidencialidad, integridad y disponibilidad. La restauración de configuración manipulada permite alteración de datos del sistema y gestión de cuentas.

Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.

🛡️ ATT&CK mitigations that cover these techniques

Affected technologies (3)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2024-50358",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-50358",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-26T14:12:13.343659Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "prodsec@nozominetworks.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "prodsec@nozominetworks.com",
      "affectedData": [
        {
          "vendor": "Advantech",
          "product": "EKI-6333AC-2G",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "semver",
              "lessThanOrEqual": "<= 1.6.3"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Advantech",
          "product": "EKI-6333AC-2GD",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "semver",
              "lessThanOrEqual": "<= 1.6.3"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Advantech",
          "product": "EKI-6333AC-1GPO",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "semver",
              "lessThanOrEqual": "<= 1.2.1"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
          ],
          "vendor": "advantech",
          "product": "eki-6333ac-2g_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "1.6.3"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
          ],
          "vendor": "advantech",
          "product": "eki-6333ac-2gd_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "1.6.3"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
          ],
          "vendor": "advantech",
          "product": "eki-6333ac-1gpo_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "1.2.1"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-11-26T11:21:59.970",
  "references": [
    {
      "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50358",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "prodsec@nozominetworks.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "prodsec@nozominetworks.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-15"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-15 \"External Control of System or Configuration Setting\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup."
    },
    {
      "lang": "es",
      "value": "Se descubrió una vulnerabilidad CWE-15 \"Control externo del sistema o de la configuración\" que afecta a los siguientes dispositivos fabricados por Advantech: EKI-6333AC-2G (&lt;= 1.6.3), EKI-6333AC-2GD (&lt;= v1.6.3) y EKI-6333AC-1GPO (&lt;= v1.2.1). Los usuarios autenticados pueden aprovechar esta vulnerabilidad restaurando una copia de seguridad de la configuración alterada."
    }
  ],
  "lastModified": "2026-06-17T08:04:18.050",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "828B9D05-0064-4690-A624-D3BF659BD316",
              "versionEndExcluding": "1.2.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:advantech:eki-6333ac-1gpo:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D2A73A2B-9FD5-4971-8FFF-1BA14BCCB37B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "447F8AEB-2C7C-411A-893C-11C2F7588C82",
              "versionEndExcluding": "1.6.5"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:advantech:eki-6333ac-2gd:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "02F70DBA-2D4C-4407-885D-71887A1A7979"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B5E027C8-2521-45FC-BABB-4A6E3341F883",
              "versionEndExcluding": "1.6.5"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:advantech:eki-6333ac-2g:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B3B63DF4-0184-4108-B48B-D31179104701"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "prodsec@nozominetworks.com"
}