CVE-2024-48970
Estado: AplazadaCrítica (9.3)—
The ventilator's microcontroller lacks memory protection. An attacker could connect to the internal JTAG interface and read or write to flash memory using an off-the-shelf debugging tool, which could disrupt the function of the device and/or cause unauthorized information disclosure.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
- Puntuación base: 9.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.21%
- Percentil entre todas las CVEs puntuadas: 11
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation60 %
Inferido por reglas deterministas a partir del vector CVSS y la CWE. Solo orientativo.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
CWE
- CWE-1191
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-48970",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-48970",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-11-18T15:22:31.746766Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productsecurity@baxter.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 9.3,
"attackVector": "LOCAL",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 2.5
}
]
},
"affected": [
{
"source": "productsecurity@baxter.com",
"affectedData": [
{
"vendor": "Baxter",
"product": "Life2000 Ventilation System",
"versions": [
{
"status": "affected",
"version": "06.08.00.00 and prior"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:baxter:life2000_ventilator_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "baxter",
"product": "life2000_ventilator_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "06.08.00.00"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2024-11-14T22:15:18.137",
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-319-01",
"source": "productsecurity@baxter.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "productsecurity@baxter.com",
"description": [
{
"lang": "en",
"value": "CWE-1191"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The ventilator's microcontroller lacks memory protection. An attacker could connect to the internal JTAG interface and read or write to flash memory using an off-the-shelf debugging tool, which could disrupt the function of the device and/or cause unauthorized information disclosure."
},
{
"lang": "es",
"value": "El microcontrolador del respirador carece de protección de memoria. Un atacante podría conectarse a la interfaz JTAG interna y leer o escribir en la memoria flash mediante una herramienta de depuración comercial, lo que podría interrumpir el funcionamiento del dispositivo o provocar la divulgación no autorizada de información."
}
],
"lastModified": "2026-06-17T07:59:08.433",
"sourceIdentifier": "productsecurity@baxter.com"
}