CVE-2024-47195
Estado: AnalizadaMedia (5.4)—
A vulnerability has been identified in ModelSim (All versions < V2024.3), Questa (All versions < V2024.3). gdb.exe in affected applications allows a specific executable file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch gdb.exe from a user-writable directory.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.15%
- Percentil entre todas las CVEs puntuadas: 4
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-427
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-47195",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-47195",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-10-08T16:50:30.816352Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.7,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.3
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.4,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "ModelSim",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2024.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Questa",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2024.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:siemens:modelsim:*:*:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "modelsim",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "2024.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:a:siemens:questa:*:*:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "questa",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "2024.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-10-08T09:15:17.300",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-426509.html",
"tags": [
"Third Party Advisory"
],
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-427"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in ModelSim (All versions < V2024.3), Questa (All versions < V2024.3). gdb.exe in affected applications allows a specific executable file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch gdb.exe from a user-writable directory."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en ModelSim (todas las versiones < V2024.3), Questa (todas las versiones < V2024.3). gdb.exe en las aplicaciones afectadas permite que se cargue un archivo ejecutable específico desde el directorio de trabajo actual. Esto podría permitir que un atacante local autenticado inyecte código arbitrario y aumente los privilegios en instalaciones donde los administradores o procesos con privilegios elevados ejecutan gdb.exe desde un directorio en el que el usuario puede escribir."
}
],
"lastModified": "2026-06-17T07:56:43.220",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:modelsim:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F71515BC-BF05-4F67-B931-F5F6FE5143F4",
"versionEndExcluding": "2024.3"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:questa:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0A126954-0467-4268-8135-AAFFCB52C10C",
"versionEndExcluding": "2024.3"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}