CVE-2024-46891
Estado: AnalizadaMedia (6.9)—
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 6.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.52%
- Percentil entre todas las CVEs puntuadas: 42
- Fecha de la puntuación: 1/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-400
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-46891",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-46891",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-11-12T14:22:45.870908Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 6.9,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "LOW",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SINEC INS",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V1.0 SP2 Update 3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:seimens:sinec_ins:*:*:*:*:*:*:*:*"
],
"vendor": "seimens",
"product": "sinec_ins",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V1.0_SP2_Update 3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-11-12T13:15:09.693",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-915275.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SINEC INS (todas las versiones < V1.0 SP2 Update 3). La aplicación afectada no restringe adecuadamente el tamaño de los archivos de registro generados. Esto podría permitir que un atacante remoto no autenticado active una gran cantidad de eventos registrados para agotar los recursos del sistema y crear una condición de denegación de servicio."
}
],
"lastModified": "2026-06-17T07:56:09.370",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:*:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B0309582-8D59-405A-886D-158C25B8B281",
"versionEndIncluding": "1.0"
},
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "75BC588E-CDF0-404E-AD61-02093A1DF343"
},
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A334F7B4-7283-4453-BAED-D2E01B7F8A6E"
},
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A6BEA71C-CA81-4B5D-A688-2B21E62DC351"
},
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6B405F22-5517-49F5-A7CA-1E50D58DFC75"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}