« Volver al listado

CVE-2024-46888

Estado: AnalizadaCrítica (9.4)—

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly sanitize user provided paths for SFTP-based file up- and downloads. This could allow an authenticated remote attacker to manipulate arbitrary files on the filesystem and achieve arbitrary code execution on the device.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Vulnerabilidad de path traversal (CWE-22) en SFTP que requiere autenticación remota (PR:L) sin UI. Permite manipulación de archivos arbitrarios (T1565.002) y ejecución de código (T1059), explotada mediante T1210 (servicio remoto con privilegios previos).

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-46888",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-46888",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-12T14:31:00.141310Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 9.9,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 3.1
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 9.9,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 3.1
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 9.4,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SINEC INS",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V1.0 SP2 Update 3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:seimens:sinec_ins:*:*:*:*:*:*:*:*"
          ],
          "vendor": "seimens",
          "product": "sinec_ins",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V1.0 SP2 Update 3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-11-12T13:15:08.927",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-915275.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly sanitize user provided paths for SFTP-based file up- and downloads. This could allow an authenticated remote attacker to manipulate arbitrary files on the filesystem and achieve arbitrary code execution on the device."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SINEC INS (todas las versiones &lt; V1.0 SP2 Update 3). La aplicación afectada no desinfecta adecuadamente las rutas proporcionadas por el usuario para la carga y descarga de archivos basados en SFTP. Esto podría permitir que un atacante remoto autenticado manipule archivos arbitrarios en el sistema de archivos y logre la ejecución de código arbitrario en el dispositivo."
    }
  ],
  "lastModified": "2026-06-17T07:56:09.000",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C89891C1-DFD7-4E1F-80A9-7485D86A15B5",
              "versionEndExcluding": "1.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4664B195-AF14-4834-82B3-0B2C98020EB6"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "75BC588E-CDF0-404E-AD61-02093A1DF343"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A334F7B4-7283-4453-BAED-D2E01B7F8A6E"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A6BEA71C-CA81-4B5D-A688-2B21E62DC351"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_2:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6B405F22-5517-49F5-A7CA-1E50D58DFC75"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}