Estado: AnalizadaCrítica (10)—

A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured).

Leer descripción completaMostrar menos

The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Vector CVSS:4.0 AV:N/PR:N/UI:N indica explotación remota sin autenticación (T1190). CWE-502 (deserialización insegura) permite ejecución de código arbitrario (T1059) con privilegios SYSTEM (T1068).

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-44102",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-44102",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-15T19:24:38.461958Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 10,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 3.9
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 10,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "PP TeleControl Server Basic 1000 to 5000 V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "PP TeleControl Server Basic 256 to 1000 V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "PP TeleControl Server Basic 32 to 64 V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "PP TeleControl Server Basic 64 to 256 V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "PP TeleControl Server Basic 8 to 32 V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "TeleControl Server Basic 1000 V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "TeleControl Server Basic 256 V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "TeleControl Server Basic 32 V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "TeleControl Server Basic 5000 V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "TeleControl Server Basic 64 V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "TeleControl Server Basic 8 V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "TeleControl Server Basic Serv Upgr",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "TeleControl Server Basic Upgr V3.1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*"
          ],
          "vendor": "siemens",
          "product": "telecontrol_server_basic",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.1.2.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-11-12T13:15:08.203",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-454789.html",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-502"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en PP TeleControl Server Basic 1000 a 5000 V3.1 (6NH9910-0AA31-0AE1) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), PP TeleControl Server Basic 256 a 1000 V3.1 (6NH9910-0AA31-0AD1) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), PP TeleControl Server Basic 32 a 64 V3.1 (6NH9910-0AA31-0AF1) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), PP TeleControl Server Basic 64 a 256 V3.1 (6NH9910-0AA31-0AC1) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), PP TeleControl Server Basic 8 a 32 V3.1 (6NH9910-0AA31-0AB1) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (Todas las versiones &lt; V3.1.2.1 con redundancia configurada). El sistema afectado permite a los usuarios remotos enviar objetos manipulados con fines malintencionados. Debido a la deserialización insegura del contenido proporcionado por el usuario por parte del software afectado, un atacante no autenticado podría aprovechar esta vulnerabilidad enviando un objeto serializado manipulado con fines malintencionados. Esto podría permitir al atacante ejecutar código arbitrario en el dispositivo con privilegios de SYSTEM."
    }
  ],
  "lastModified": "2026-06-17T07:52:18.693",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3C62D5AE-CDAF-4FB3-A27D-C7EB33701D9C",
              "versionEndExcluding": "3.1.2.1",
              "versionStartIncluding": "3.1"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}