CVE-2024-4241
Estado: AnalizadaAlta (8.8)—
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.35%
- Percentil entre todas las CVEs puntuadas: 70
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-121
- CWE-787
Referencias
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formQosManageDouble_user.md
- https://vuldb.com/?ctiid.262132
- https://vuldb.com/?id.262132
- https://vuldb.com/?submit.319823
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formQosManageDouble_user.md
- https://vuldb.com/?ctiid.262132
- https://vuldb.com/?id.262132
- https://vuldb.com/?submit.319823
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-4241",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-4241",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-07-16T20:45:20.935521Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Tenda",
"product": "W9",
"versions": [
{
"status": "affected",
"version": "1.0.0.7(4456)"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:h:tenda:w9:-:*:*:*:*:*:*:*"
],
"vendor": "tenda",
"product": "w9",
"versions": [
{
"status": "affected",
"version": "1.0.0.7(4456)"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-04-26T21:15:50.507",
"references": [
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formQosManageDouble_user.md",
"tags": [
"Broken Link"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.262132",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.262132",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.319823",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formQosManageDouble_user.md",
"tags": [
"Broken Link"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?ctiid.262132",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?id.262132",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?submit.319823",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se encontró una vulnerabilidad en Tenda W9 1.0.0.7(4456). Ha sido declarada crítica. Esta vulnerabilidad afecta a la función formQosManageDouble_auto. La manipulación del argumento ssidIndex provoca un desbordamiento de búfer en la región stack de la memoria. El ataque se puede iniciar de forma remota. El identificador de esta vulnerabilidad es VDB-262132. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera."
}
],
"lastModified": "2026-06-17T08:01:30.380",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:w9_firmware:1.0.0.7\\(4456\\):*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2C2E04EE-4493-4CCB-9EB6-7E0D033920A1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:w9:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D015C5A3-DF6D-45B7-B669-9CCD50C5E704"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}