CVE-2024-41796
Estado: AnalizadaMedia (6.9)—
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices allows to change the login password without knowing the current password. In combination with a prepared CSRF attack (CVE-2024-41795) an unauthenticated attacker could be able to set the password to an attacker-controlled value.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 6.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.38%
- Percentil entre todas las CVEs puntuadas: 29
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-620
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-41796",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-41796",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-04-08T13:31:19.338109Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 6.9,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "ACTIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SENTRON 7KT PAC1260 Data Manager",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-04-08T09:15:20.813",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-187636.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-620"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices allows to change the login password without knowing the current password. In combination with a prepared CSRF attack (CVE-2024-41795) an unauthenticated attacker could be able to set the password to an attacker-controlled value."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SENTRON 7KT PAC1260 Data Manager (todas las versiones). La interfaz web de los dispositivos afectados permite cambiar la contraseña de inicio de sesión sin conocer la contraseña actual. En combinación con un ataque CSRF preparado (CVE-2024-41795), un atacante no autenticado podría configurar la contraseña con un valor controlado por el atacante."
}
],
"lastModified": "2026-06-17T07:48:14.927",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:7kt_pac1260_data_manager_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5E6C441C-751B-4D8B-967B-8237E181F21A"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:7kt_pac1260_data_manager:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "129B89C3-6730-47B7-9D07-41116E8230A0"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "productcert@siemens.com"
}