CVE-2024-38309
There are multiple stack-based buffer overflow vulnerabilities in V-SFT (v6.2.2.0 and earlier), TELLUS (v4.0.19.0 and earlier), and TELLUS Lite (v4.0.19.0 and earlier). If a user opens a specially crafted file, information may be disclosed and/or arbitrary code may be executed.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.21%
- Percentil entre todas las CVEs puntuadas: 10
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution95 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 % - Impacto secundario
T1005Data from Local Systemcollection85 %
AV:L + UI:R indica apertura de archivo preparado (ejecución en cliente). Stack-based buffer overflow permite ejecución de código arbitrario (T1059) e información disclosure (T1005).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (3)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-121
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-38309",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-38309",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-11-29T20:52:06.033925Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "vultures@jpcert.or.jp",
"affectedData": [
{
"vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
"product": "V-SFT",
"versions": [
{
"status": "affected",
"version": "v6.2.2.0 and earlier"
}
]
},
{
"vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
"product": "TELLUS",
"versions": [
{
"status": "affected",
"version": "v4.0.19.0 and earlier"
}
]
},
{
"vendor": "FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.",
"product": "TELLUS Lite",
"versions": [
{
"status": "affected",
"version": "v4.0.19.0 and earlier"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:fujielectric:v-sft:*:*:*:*:*:*:*:*"
],
"vendor": "fujielectric",
"product": "v-sft",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "6.2.2.0"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:a:fujielectric:tellus:*:*:*:*:*:*:*:*"
],
"vendor": "fujielectric",
"product": "tellus",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "4.0.19.0"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:a:fujielectric:tellus_lite:*:*:*:*:*:*:*:*"
],
"vendor": "fujielectric",
"product": "tellus_lite",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "4.0.19.0"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-11-28T03:15:15.963",
"references": [
{
"url": "https://jvn.jp/en/vu/JVNVU97531313/",
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php",
"source": "vultures@jpcert.or.jp"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "vultures@jpcert.or.jp",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "There are multiple stack-based buffer overflow vulnerabilities in V-SFT (v6.2.2.0 and earlier), TELLUS (v4.0.19.0 and earlier), and TELLUS Lite (v4.0.19.0 and earlier).\r\nIf a user opens a specially crafted file, information may be disclosed and/or arbitrary code may be executed."
},
{
"lang": "es",
"value": "Existen múltiples vulnerabilidades de desbordamiento de búfer basadas en pila en V-SFT (v6.2.2.0 y anteriores), TELLUS (v4.0.19.0 y anteriores) y TELLUS Lite (v4.0.19.0 y anteriores). Si un usuario abre un archivo especialmente manipulado, se puede divulgar información y/o ejecutar código arbitrario."
}
],
"lastModified": "2026-06-17T07:39:55.097",
"sourceIdentifier": "vultures@jpcert.or.jp"
}