CVE-2024-3521
A vulnerability was found in Byzoro Smart S80 Management Platform up to 20240317. It has been rated as critical. Affected by this issue is some unknown functionality of the file /useratte/userattestation.php. The manipulation of the argument web_img leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-259892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
- Puntuación base: 4.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.24%
- Percentil entre todas las CVEs puntuadas: 68
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-434
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-3521",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-3521",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-07-15T17:15:38.634733Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 5.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
"authentication": "MULTIPLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.4,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.7,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "HIGH",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Byzoro",
"product": "Smart S80 Management Platform",
"versions": [
{
"status": "affected",
"version": "20240317"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:byzoro:smart_s80:*:*:*:*:*:*:*:*"
],
"vendor": "byzoro",
"product": "smart_s80",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "20240317",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-04-09T23:15:25.737",
"references": [
{
"url": "https://github.com/garboa/cve_3/blob/main/Upload2.md",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.259892",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.259892",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.308509",
"source": "cna@vuldb.com"
},
{
"url": "https://github.com/garboa/cve_3/blob/main/Upload2.md",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?ctiid.259892",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?id.259892",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?submit.308509",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-434"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Byzoro Smart S80 Management Platform up to 20240317. It has been rated as critical. Affected by this issue is some unknown functionality of the file /useratte/userattestation.php. The manipulation of the argument web_img leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-259892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se ha encontrado una vulnerabilidad en Byzoro Smart S80 Management Platform hasta 20240317 y se ha calificado como crítica. Una función desconocida del archivo /useratte/userattestation.php es afectada por esta vulnerabilidad. La manipulación del argumento web_img conduce a una carga sin restricciones. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador de esta vulnerabilidad es VDB-259892. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera."
}
],
"lastModified": "2026-06-17T07:44:26.250",
"sourceIdentifier": "cna@vuldb.com"
}