CVE-2024-34772
Status: AnalyzedHigh (7.8)—
A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Base score: 7.8
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.29%
- Percentile among all scored CVEs: 20
- Score date: 10/6/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
CWEs
- CWE-125
References
Raw JSON (NVD)
Show
{
"id": "CVE-2024-34772",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-34772",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-05-14T12:54:19.687164Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Solid Edge",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V224.0 Update 4",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "solid_edge",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "v224.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-05-14T16:17:29.610",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-589937.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-589937.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Solid Edge (Todas las versiones < V224.0 Actualización 4). Las aplicaciones afectadas contienen una lectura fuera de los límites más allá del final de una estructura asignada mientras analizan archivos PAR especialmente manipulados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual."
}
],
"lastModified": "2026-06-17T07:34:02.427",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D3887095-4E46-43B0-8A1E-4938EB474419",
"versionEndExcluding": "224.0"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A0119E8F-1FAF-4A3B-B6E9-20F78360FC82"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "829C4AEB-7C8D-408B-A79C-8684753F45E1"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1E8FB23E-280D-46FD-BD44-5D4552639E00"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CA2417A0-DD31-46FC-8D5A-9128B86C9352"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}